Ntp- D223 Attach Wires To Alarm, Timing, Lan, And Craft Pin Connections - Cisco ONS 15454 SDH Procedure Manual

Hide thumbs Also See for ONS 15454 SDH:
Table of Contents

Advertisement

Chapter 1
Install the Shelf and FMECs
NTP-D223 Attach Wires to Alarm, Timing, LAN, and Craft Pin
Connections
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Always use the supplied ESD wristband when working with a powered ONS 15454 SDH. Plug the
Caution
wristband cable into the ESD jack located on the lower-right outside edge of the shelf assembly.
Complete the
Step 1
Complete the
Step 2
Timing wires are necessary to provision external timing.
Complete the
Step 3
wires (or the LAN port on the TCC2/TCC2P card) are necessary to create an external LAN connection.
Complete the
Step 4
needed. Craft wires (or the EIA/TIA-232 port on the TCC2/TCC2P cards) are required to access
Transaction Language One (TL1) using the craft interface.
Continue with the
Step 5
page
Stop. You have completed this procedure.
78-17194-01
This procedure installs alarm, timing, LAN, and craft wires.
Connectors according to function
Twisted 0.51 mm² or 0.64 mm² (#22 or #24 AWG) shielded wires for LAN
or craft
75-ohm coaxial cable with 1.0/2.3 miniature coax connector
0.51 mm² or 0.64 mm² (#22 or #24 AWG) alarm wires
NTP-D220 Install the Power and Signal FMECs, page 1-7
As needed
Onsite
None
"DLP-D324 Install Alarm Cables on the MIC-A/P" task on page 20-12
"DLP-D325 Install Timing Cables on the MIC-C/T/P" task on page 20-15
"DLP-D326 Install LAN Wires on the MIC-C/T/P" task on page 20-16
"DLP-D78 Install the TL1 Craft Interface on the MIC-C/T/P" task on page 17-70
"NTP-D224 Install the Electrical Card Cables on the FMECs" procedure on
1-16.

NTP- D223 Attach Wires to Alarm, Timing, LAN, and Craft Pin Connections

Cisco ONS 15454 SDH Procedure Guide, R7.0
as necessary.
as needed.
as needed. LAN
as
1-15