NTP- D324 Create a Manually Routed High-Order Circuit

NTP-D324 Create a Manually Routed High-Order Circuit
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Complete the
Step 1
where you will create the circuit. If you are already logged in, continue with
If you want to assign a name to the circuit source and destination ports before you create the circuit,
Step 2
complete the
automatically based on circuit type, node name, and sequence number, continue with
Step 3
If you are creating a circuit on G-Series cards, complete the
Ports" task on page 19-21
If you are creating a circuit onML-Series, CE-100T-8 or CE-1000-4 circuits, complete the following as
Step 4
necessary (you can provision Ethernet or POS ports before or after the VCAT circuit is created):
From the View menu, choose Go to Network View.
Step 5
In the Circuit Creation dialog box, complete the following fields:
Step 6
Click Next.
Step 7
Define the circuit attributes:
Step 8
Cisco ONS 15454 SDH Procedure Guide, R7.0
6-60
This procedure creates a manually routed, bidirectional or unidirectional
high-order circuit, including VC4 and concatenated VC4-2c, VC4-3c,
VC4-4c, VC4-8c, VC4-16c, and VC4-64c speeds.
None
NTP-D127 Verify Network Turn-Up, page 6-5
As needed
Onsite or remote
Provisioning or higher
"DLP-D60 Log into CTC" task on page 17-49
"DLP-D314 Assign a Name to a Port" task on page
before or after you create the G-Series circuit.
To provision Ethernet ports for CE-100T-8 circuits, complete the
Ethernet Ports" task on page
To provision Ethernet ports for CE-1000-4 circuits, complete the
Ethernet Ports" task on page
To provision POS ports for CE-100T-8 or CE-1000-4 circuits, complete the
CE-100T-8 and CE-1000-4 POS Ports" task on page
To provision Ethernet ports for ML-Series circuits, complete the
Port of the ML-Series Card" task on page
To provision POS ports for ML-Series circuits, complete the
the ML-Series Card" task on page
Circuit Type—Choose VC_HO_PATH_CIRCUIT.
Number of Circuits—Enter the number of high-order circuits that you want to create.
The default is 1.
Auto-ranged—(Applies to automatically routed circuits only) If you entered more than 1 in Number
of Circuits, uncheck this check box. (The check box is unavailable if only one circuit is entered in
Number of Circuits.)
Name—Assign a name to the circuit. The name can be alphanumeric and up to 48 characters
(including spaces). Circuit names should be 44 characters or less if you want the ability to create
monitor circuits. If you leave the field blank, CTC assigns a default name to the circuit.
18-30.
19-8.
18-33.
21-49.
21-50.
Chapter 6
Create Circuits and Low-Order Tunnels
at an ONS 15454 SDH on the network
Step
2.
20-7. If you want CTC to assign a name
Step
"DLP-D222 Provision G-Series Ethernet
"DLP-D136 Provision CE-100T-8
"DLP-D211 Provision CE-1000-4
"DLP-D141 Provision
"DLP-D493 Provision the Ethernet
"DLP-D494 Provision the POS Port of
3.
78-17194-01