Dlp- D367 Provision A J2 Path Trace On Circuit Source And Destination Ports - Cisco ONS 15454 SDH Procedure Manual

Hide thumbs Also See for ONS 15454 SDH:
Table of Contents

Advertisement

DLP- D367 Provision a J2 Path Trace on Circuit Source and Destination Ports

If you checked OSI, complete the following steps. If you checked IP only, continue with
Step 8
a.
b.
Click Finish.
Step 9
Note
Return to your originating procedure (NTP).
Step 10
DLP-D367 Provision a J2 Path Trace on Circuit Source and Destination Ports
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Note
This task assumes that you are setting up path trace on a bidirectional circuit and setting up transmit
strings at the circuit source and destination.
Step 1
From the View menu, choose Go to Network View.
Step 2
Click the Circuits tab.
Cisco ONS 15454 SDH Procedure Guide, R7.0
20-72
OSI-only (LAP-D) is not available for MS-DCCs.
Note
Click Next.
Provision the following fields:
Router—Choose the OSI router.
ESH—Sets the ESH propagation frequency. End system NEs transmit ESHs to inform other ESs
and ISs about the NSAPs it serves. The default is 10 seconds. The range is 10 to 1000 seconds.
ISH—Sets the ISH PDU propagation frequency. Intermediate system NEs send ISHs to other
ESs and ISs to inform them about the IS NETs it serves. The default is 10 seconds. The range
is 10 to 1000 seconds.
IIH—Sets the IIH PDU propagation frequency. The IS-IS Hello PDUs establish and maintain
adjacencies between ISs. The default is 3 seconds. The range is 1 to 600 seconds.
Metric—Sets the cost for sending packets on the LAN subnet. The IS-IS protocol uses the cost
to calculate the shortest routing path. The default metric cost for LAN subnets is 20. It normally
should not be changed.
Multiplex-Section DCC Termination Failure (MS-EOC) and LOS alarms appear until you create
all network DCC terminations and put the DCC termination STM-N ports in service.
This task creates a J2 path trace on VC12 circuit source ports and
destination ports.
ONS 15454 SDH cards capable of transmitting and/or receiving path trace
must be installed at the circuit source and destination ports. See
Table 20-30 on page 20-73
DLP-D60 Log into CTC, page 17-49
As needed
Onsite or remote
Provisioning or higher
Chapter 20
for a list of cards.
DLPs D300 to D399
Step
9.
78-17194-01

Advertisement

Table of Contents
loading