DLP- D441 Create Ethernet RMON Alarm Thresholds

DLP-D441 Create Ethernet RMON Alarm Thresholds
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
The ONS 15454 SDH ML-Series cards use the Cisco IOS CLI for managing RMON.
Note
Complete the
Step 1
monitoring.
Double-click the Ethernet card where you want to create the RMON alarm thresholds.
Step 2
In card view, click the Provisioning > RMON Thresholds tabs.
Step 3
Click Create.
Step 4
The Create Ether Threshold dialog box appears
Figure 21-9
From the Slot drop-down list, choose the appropriate Ethernet card.
Step 5
From the Port drop-down list, choose the applicable port on the Ethernet card that you selected.
Step 6
Step 7
From the Variable drop-down list, choose the variable. See
Ethernet threshold variables available in this field.
Cisco ONS 15454 SDH Procedure Guide, R7.0
21-28
This task sets up RMON to allow network management systems (NMSs) to
monitor Ethernet ports.
None
NTP-D24 Verify Card Installation, page 4-2
As needed
Onsite or remote
Provisioning or higher
"DLP-D60 Log into CTC" task on page 17-49
Creating Ethernet RMON Thresholds
at the node where you want to set up remote
(Figure
21-9).
Table 21-2 on page 21-29