Chapter 9
Manage Alarms
The Circuits window appears with the affected circuits highlighted.
If you want to search for particular circuits, see the
Step 4
Stop. You have completed this procedure.
NTP-D70 View Alarm Counts on the LCD for a Node, Slot, or Port
Purpose
Tools/Equipment
Prerequisite Procedures None
Required/As Needed
Onsite/Remote
Security Level
If you want to view the entire alarm summary for the node, press either the Slot button or Port button
Step 1
on the LCD panel until "Node" appears on the LCD. You will also see the direction, "Status=Alm Ct."
This means that if you press the Status button at this time, as directed in
count for the node.
Press the Status button. You will see a message similar to, "Alm CT: 2: MJ:2 MN:2," meaning there are
Step 2
two critical alarms, two major alarms, and two minor alarms.
If you want to see alarm counts for a particular slot, such as the alarms for an STM-1 card in Slot 2, press
Step 3
the Slot button until you see "Slot-3" on the LCD. You will also see the direction, "Status=Alm Ct."
Step 4
Press the Status button to see a summary of alarms and severities against the slot. For example, you
might see, "Slot-3 Alm CT:0 MJ:1 MN:2," meaning that there are no critical alarms, one major alarm,
and two minor alarms against the slot.
If you want to view the alarms against a port on the card, such as Port 3 of the STM-3 card you viewed
Step 5
previously, press Port until you see "Port-3 Status=Alm Ct."
Press Status to view alarm count against the port. You will see a message similar to, "Port-3 Alm CT:0
Step 6
MJ:1 MN:0." This means that there is one major alarm against this port.
Figure 9-2
Figure 9-2
To return to the previous view from the Port screen, continue to press Port until the display cycles
through all the ports on the slot. For instance, on the STM-3 card, press Port until it cycles past Slot 4
and you see "Slot."
78-17194-01
Use this procedure to view an alarm summary for a node, slot, or port
without using CTC.
None
As needed
Onsite
None
shows the shelf LCD panel.
Shelf LCD Panel
Slot
Status
FAN FAIL
CRIT
MAJ

NTP- D70 View Alarm Counts on the LCD for a Node, Slot, or Port

"DLP-D131 Search for Circuits" task on page
Port
8/18/03
04.06-002L-10
MIN
Cisco ONS 15454 SDH Procedure Guide, R7.0
Step
2, you will see an alarm
24˚C
18-26.