Ntp- D55 Create A Manually Routed Low-Order Vc3 Circuit - Cisco ONS 15454 SDH Procedure Manual

Hide thumbs Also See for ONS 15454 SDH:
Table of Contents

Advertisement

Chapter 6
Create Circuits and Low-Order Tunnels
Complete the
Step 21
a test circuit.
Stop. You have completed this procedure.
NTP-D55 Create a Manually Routed Low-Order VC3 Circuit
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Complete the
Step 1
where you will create the circuit. If you are already logged in, continue with
On the shelf graphic, verify that XC-VXL-10G or XC-VXL-2.5G cross-connect cards are installed in
Step 2
Slots 8 and 10.
If you want to assign a name to the circuit source and destination ports before you create the circuit,
Step 3
complete the
automatically based on circuit type, node name, and sequence number, continue with
Step 4
From the View menu, choose Go to Network View.
Step 5
Click the Circuits tab, then click Create.
Step 6
In the Circuit Creation dialog box, complete the following fields:
Click Next.
Step 7
Define the circuit attributes
Step 8
78-17194-01
"NTP-D135 Test Low-Order Circuits" procedure on page
This procedure creates low-order VC3 circuit and allows you to provision
the circuit route.
XC-VXL-10G or XC-VXL-2.5G cards must be installed at the circuit
source and destination nodes.
NTP-D127 Verify Network Turn-Up, page 6-5
As needed
Onsite or remote
Provisioning or higher
"DLP-D60 Log into CTC" task on page 17-49
"DLP-D314 Assign a Name to a Port" task on page
Circuit Type—Choose VC_LO_PATH_CIRCUIT.
Number of Circuits—Enter the number of VC3 circuits that you want to create. The default is 1. If
you are creating multiple circuits with the same slot and consecutive port numbers, you can use
Auto-ranged to create the circuits automatically.
Auto-ranged—This check box is automatically selected if you enter more than 1 in the Number of
Circuits field. Auto-ranging creates identical (same source and destination), sequential circuits
automatically. Uncheck the box if you do not want CTC to create sequential circuits automatically.
(Figure 6-5 on page
Name—Assign a name to the circuit. The name can be alphanumeric and up to 48 characters,
(including spaces). Circuit names should be 44 characters or less if you want the ability to create
monitor circuits. If you leave the field blank, CTC assigns a default name to the circuit.
Size—Choose VC3.
Create cross-connects only (TL1-like)—Check this check box if you want to create one or more
cross-connects to complete a signal path for TL1-generated circuits. If you check this box, low-order
tunnels and Ethergroup sources and destinations are unavailable.

NTP- D55 Create a Manually Routed Low-Order VC3 Circuit

6-53. Skip this step if you built
at an ONS 15454 SDH on the network
20-7. If you want CTC to assign a name
6-32):
Cisco ONS 15454 SDH Procedure Guide, R7.0
Step
2.
Step
4.
6-35

Advertisement

Table of Contents
loading