Details - Omron NX-ECC201 User Manual

Machine automation controller nx-series ethercat coupler unit
Table of Contents

Advertisement

3 Specifications and Application Procedures
3-2-2

Details

Procedure
Preparing for
Selecting NX
Work
Units
Confirming Suit-
ability of Slave
1
Terminal Speci-
fications
Making Hard-
Setting the
ware Settings
Node Address
and Wiring the
Slave Terminal
2
Installation
Wiring
Creating the
Creating the
EtherCAT Net-
EtherCAT Net-
work Configu-
work Configura-
ration and
tion and Making
Making Set-
Settings as an
tings as an
EtherCAT Slave
EtherCAT
3
Slave
3 - 8
Item
• Select the NX Units for I/O refreshing methods, and the
quantity and types of I/O that are required.
Confirm that the following specific restrictions for the Slave
Terminal are met.
• Number of NX Units
• Send/receive PDO data sizes
• Design conditions for the NX Unit power supply and I/O
power supply
• Installation orientation
Set the node address of the EtherCAT Coupler Unit with the
hardware switches. You can also use the Sysmac Studio to
set the node address with software settings. To use software
settings, set the hardware switches to 000, and then mount
and wire the EtherCAT Coupler Unit. When you go online in
step 3, follow the procedure to automatically create the
EtherCAT network configuration from the actual network
devices with the compare and merge operation. This sets the
node address to the software setting.
Connect the NX Units and End Cover to the EtherCAT Cou-
pler Unit and secure the Slave Terminal to a DIN Track to
install it.
Wire the Slave Terminal.
• Connect the communications cables.
• Connect the Unit power supply.
• Connect the I/O power supply.
• Connect the ground wire.
• Connect the external I/O devices.
Create a project in the Sysmac Studio.
Create the EtherCAT network configuration offline.
Specifically, register the EtherCAT Coupler Unit in the net-
work configuration. Then, make the settings for the EtherCAT
Coupler Unit as an EtherCAT slave. Set the node address of
the EtherCAT Coupler Unit to the node address set in step 2.
Set other parameters as required.
If you want to use the compare and merge operation to auto-
matically create the EtherCAT network configuration online
based on the actual devices that are connected to the net-
work, you must use step 8 first to go online. After the network
configuration is created automatically, go offline and set the
other parameters.
Description
NX-series EtherCAT Coupler Unit User's Manual (W519)
Reference
• 2-2-2 Types of
NX Units on
page 2-6
• 10-3-3 Selecting
NX Units on
page 10-7
• 3-1 Specifica-
tions on page 3-2
• Section 5
Designing the
Power Supply
System
• 6-1-3 Installation
Orientation on
page 6-8
4-3 Hardware
Switch Settings on
page 4-9
6-1 Installing Units
on page 6-2
Section 7 Wiring
9-2-2 Settings as
an EtherCAT Slave
on page 9-6