Setting
NX Unit Mounting
Setting
Serial Number
Supply Power/Avail-
able Power [W]
Unit width [mm]
I/O allocation settings
Unit operation set-
tings
Number of mounted
Units
NX Unit Connection
Time (s)
Serial Number Check
Method
*1. If this setting is set to Setting = Actual device and you replace an NX Unit in the Slave Terminal, an Unit Con-
figuration Verification Error will occur. A Unit Configuration Verification Error will also occur if you swap the
mounting position of two Units of the same model. If it becomes necessary to replace an NX Unit, or swap the
mounting positions of two Units of the same model while this setting is set to Setting = Actual device, you must
correct the Unit configuration information and download it to the EtherCAT Coupler Unit. Set this parameter to
Setting = Actual device if strict management of the equipment configuration is required.
NX-series EtherCAT Coupler Unit User's Manual (W519)
Setta-
Description
ble
This setting enables or disables the mounting of an NX
Unit. You cannot directly edit these settings in the
EtherCAT Coupler Unit.
This is the serial number of the EtherCAT Coupler Unit.
You can get the serial number to set the serial number
of the actual EtherCAT Coupler Unit.
The power that is currently drawn by the NX Units and
the maximum available power supply capacity are
given.
This is the width of the EtherCAT Coupler Unit.
Yes
These are the I/O allocation settings for the EtherCAT
Coupler Unit. Click the Edit I/O Allocation Settings
Button to edit these settings.
Yes
These are the Unit operation settings for the EtherCAT
Coupler Unit. Click the Edit Unit Operation Settings
Button to edit these settings.
This is the number of mounted NX Units.
Yes
This is the wait time for the NX Units to connect to the
Slave Terminal.
Yes
Set this setting to Setting = Actual device to compare
the serial numbers of the NX Units at these times: when
the power is turned ON and after the EtherCAT Coupler
Unit is restarted. The serial numbers of the NX Units
saved in the Unit configuration information are com-
pared with the actual serial numbers of the NX Units.
If differences are found, a Unit Configuration Verifica-
tion Error will occur.
9 Setting Up Slave Terminals
Data
range
---
---
---
---
---
-/10.00
---
46
---
Refer to 9-2-4 I/O
Allocation Infor-
mation on page
9-13.
---
Refer to 9-2-5
Unit Operation
Settings on page
9-23.
---
---
3 to 200 s
3 s
No check.
No check.
Setting =
Actual
device
*1
Default
9