Omron NX-ECC201 User Manual page 327

Machine automation controller nx-series ethercat coupler unit
Table of Contents

Advertisement

AL status
Status name
code (hex)
0034
Synchronization
Error during Oper-
ation
0035
Synchronization
Cycle Setting Error
8000
Slave Restarted
NX-series EtherCAT Coupler Unit User's Manual (W519)
Error log
Contents
record
During operation in
Not saved.
Operational state,
inputs of the SYNC0
signal continued, but
refreshing of the
RxPDO data failed
consecutively for the
specified number of
times.
When DC Mode was
Not saved.
confirmed, the syn-
chronization cycle
was set to a value
that made operation
impossible.
A restart was imple-
Not saved.
mented with a slave
restart command.
13 Troubleshooting
Notifica-
tion to
Corrective action
EtherCAT
master
Possible.
Review the following items, and
restart the slave based on the speci-
fications of the connected EtherCAT
master.
• Wire the EtherCAT communica-
tions cable correctly.
• Check to see if the EtherCAT
communications cable is exposed
to excessive noise.
Possible.
Correct the settings, and then down-
load the settings to the EtherCAT
master again.
Possible.
---
13