Omron NX-ECC201 User Manual page 65

Machine automation controller nx-series ethercat coupler unit
Table of Contents

Advertisement

Procedure
Configuring the Slave Terminal
and Making the Operation Set-
tings
Creating the
Unit Configura-
tion Information
4
Setting the I/O
Allocation Infor-
mation
Unit Operation
Settings
Setting Unit
Application Data
Setting Ether-
Setting Ether-
CAT Master
CAT Master
5
Parameters
Parameters
Assigning Slave Terminal Vari-
ables
Assigning
Device Vari-
6
ables to I/O
Ports
Assigning Axis
Variables
Programming
Programming
7
Task Settings
NX-series EtherCAT Coupler Unit User's Manual (W519)
Item
Set up the Slave Terminal (create the configuration and set
the parameters) on the Edit Slave Terminal Configuration Tab
Page on the Sysmac Studio.
Create the Unit configuration information of the Slave Termi-
nal (EtherCAT Coupler Unit and NX Units) offline.
Make the I/O allocations for the EtherCAT Coupler Unit and
NX Units as required.
Make the Unit operation settings for the EtherCAT Coupler
Unit and NX Units as required.
Create the Unit application data. (This step applies only to
Units that have Unit application data.)
Set the EtherCAT master parameters (process data commu-
nications cycle, wait time for slave startup, etc.). The values
that are set are reflected in the network configuration infor-
mation.
To enable access in the user program in the NJ-series CPU
Unit, the I/O data that is assigned in the I/O allocation infor-
mation is assigned to device variables and axis variables.
If necessary, change the names of automatically generated
device variables for each I/O port to user-defined variable
names.
If you will control Position Interface Units with the Motion
Control Function Module, create the axes and assign I/O
data to the axis variables.
Write the user program with device variables and axis vari-
ables.
Make the task settings. If you will use synchronous I/O
refreshing in DC Mode to refresh I/O for EtherCAT Slave Ter-
minals, set the task period of the primary periodic task so that
it is longer than the refresh cycle of the NX bus.
3 Specifications and Application Procedures
Description
Reference
Slave Terminal
Configuring and
Operation Settings
on page 9-5
9-2-3 Setting the
Unit Configuration
Information on
page 9-8
9-2-4 I/O Alloca-
tion Information on
page 9-13
9-2-5 Unit Opera-
tion Settings on
page 9-23
9-2-6 Unit Applica-
3
tion Data on page
9-25
NJ-series CPU Unit
Built-in EtherCAT
Port User's Man-
ual (W505)
9-3 Assigning Vari-
ables on page 9-29
9-3-2 Assigning
Device Variables to
I/O Ports on page
9-30
9-3-4 Assigning
Axis Variables on
page 9-33
• NJ-series CPU
Unit Software
User's Manual
(W501)
• NJ-series CPU
Unit Built-in
EtherCAT Port
User's Manual
(W505)
• NJ-series CPU
Unit Software
User's Manual
(W501)
• 10-3-4 I/O
Refreshing
Method Opera-
tion on page 10-7
3 - 9

Advertisement

Table of Contents
loading

Table of Contents