Unit Operation Settings

Unit Operation Settings for the EtherCAT Coupler Unit
The operation settings of the EtherCAT Coupler Unit are listed below.
Setting
Synchronization
Error Setting
Communications
Error Setting
Unit Operation Settings for the NX Unit
The settings that are available depend on the type of the NX Unit.
For example, Digital Input Units have a setting for the input filter value, and Digital Output Units have a
setting for the output value at load rejection.
Refer to the manual for the specific NX Unit for the settings and their meanings.
NX-series EtherCAT Coupler Unit User's Manual (W519)
Setting range
0 to 600 s (0 implies
0
120 s.)
0 to 15
1
9 Setting Up Slave Terminals
Default
A Synchronization Interruption Error occurs
if the Sync0 signal input does not turn ON
within this set value after the EtherCAT Cou-
pler Unit enters the Safe-Operational state.
A Process Data WDT Error occurs if the
communications error occurs consecutively
for more than this set value.
Description
9 - 23
9