Set The Ip Address Of The Computer; Default Ip Address Settings Of The Amplifier Unit; Setting The Ip Address Of The Computer With Windows 10 - Omron V640 Series Operation Manual

Cidrw system
Hide thumbs Also See for V640 Series:
Table of Contents

Advertisement

2 Basic Operation of V640 Utility Tool
2-1

Set the IP address of the computer

The default IP addresses of the Amplifier Unit are given in the following table. Use these addresses to
set the IP address on the computer.
This example changes the last part of the IP address to a value other than 200 (i.e., to 1 to 199 or 201
to 254).
Values of 0 and 255 cannot be used.
2-1-1

Default IP Address Settings of the Amplifier Unit

Setting item Default setting
IP address
192.168.1.200
Subnet mask 255.255.255.0
2-1-2

Setting the IP Address of the Computer with Windows 10

1
Open the Control Panel, and select Network and Internet and then Network and Sharing
Center.
2
Select Change adapter settings and then right-click Local Area Connection.
3
Right-click Local Area Connection and select Properties.
4
Select Internet Protocol Version 4(TCP/IPv4) and then click the Properties Button.
Change the last part of the IP address to a value other than 200 (i.e., to 1 to 199 or 201 to
254).
Values of 0 and 255 cannot be used.
5
Click the "OK Button to colse the Internet Protocol Version 4(TCP/IPv4) Properties Dialog
Box.
2-2
V640 SERIES CIDRW SYSTEM OPERATION MANUAL V640 Utility Tool (Z469-E1)

Advertisement

Table of Contents
loading

This manual is also suitable for:

V640-ham11-etn-v2V640-ham11-l-etn-v2

Table of Contents