10. Service Mode
10.9.5

Unit Change

Functions
• To select who is to replace a unit.
• When the unit life arrives, the warning display is intended for the specific person who
is going to replace the unit.
When "User" is selected
When "Service" is selected: Life warning.
Use
• Upon setup
Setting/
• The following are the default settings:
Procedure
Toner Cartridge
Imaging Unit
Waste Toner Box
Punch Dust Box
10.9.6

Software Switch Setting

1
Functions
Use
• Not Used.
Setting/
Procedure
10.9.7

Scan Calibration

Functions
• To set whether to use the calibration adjustment value set prior to the shipping.
Use
• To be used when CCD unit has bee changed.
After replacing the CCD unit, the default value needs to be set since the calibration
value set for each unit changes to control the differences in reading performance on
each scanner (CCD).
Setting/
• The default setting is ON.
Procedure
NOTE
• When the setting is changed, the function becomes available by turning the
Sub Power Switch OFF and ON again.
10.9.8

LCT Paper Size Setting

Functions
• To set the paper size for the LCT
Use
• Use to change the paper size for the LCT.
Setting/
The default setting depends on the setting made for the applicable marketing area.
Procedure
340
: Copying is inhibited.
US, Japan, Others 4
: "User" Service
: User
"Service"
: User
"Service"
: User
"Service"
"ON"
A4
Field Service Ver. 3.0 Aug. 2006
Europe, Others1/2/3
"User"
Service
"User"
Service
"User"
Service
"User"
Service
OFF
8
/
x 11
1
2