l
Link Monitoring: The ZXR10 2900E series switch monitors and examines the link
state, and announces the specified frame events by OAM function. The specified
frame events can be classified into four types: error symbol period event, error
frame event and error frame period event, error frame-second statistic event. After
inspecting the error, OAM will respond and alarm the peer device by announcement
mechanism.
The link monitoring events are classified into four types: error symbol monitor event, error
frame monitor event, error frame-period monitor event and error frame-second statistic
monitor event. When the link monitoring information is viewed, the related error symbol,
the statistic of error frame and the statistic of local and peer link events will be shown on
each event.
Configuring OAM
The OAM configuration includes the following commands:
Command
zte(cfg)#
zte(cfg)#
zte(cfg)#
timeout <2-20> mode {active | passive}
zte(cfg)#
zte(cfg)#
| stop}
zte(cfg)#
time-stamp <1-10>}
zte(cfg)#
disable}
zte(cfg)#
symbol-period threshold <1-65535> window <1-65535>
zte(cfg)#
threshold <1-65535> window <1-60>
zte(cfg)#
frame-period threshold <1-65535> window <1-600000>
zte(cfg)#
frame-seconds threshold <1-900> window <10-900>
SJ-20130731155059-002|2013-11-27 (R1.0)
set ethernet-oam {enable | disable}
set ethernet-oam port <portlist>{enable | disable}
set ethernet-oam port <portlist> period <1-10>
set ethernet-oam remote-loopback timeout <1-10>
set ethernet-oam remote-loopback port <portlist>{start
set ethernet-oam org-specific {oui <XX-XX-XX>|
set ethernet-oam port <portlist> link-monitor {enable |
set ethernet-oam port <portlist> link-monitor
set ethernet-oam port <portlist> link-monitor frame
set ethernet-oam port <portlist> link-monitor
set ethernet-oam port <portlist> link-monitor
Chapter 5 Service Configuration
5-127
ZTE Proprietary and Confidential
Function
Enables or disables the global
OAM function.
Enables or disables the OAM
function on the port.
Sets the OAM period, timeout time
and mode of the port.
Sets remote-loopback timeout
value on port.
Starts or stops OAM
remote-loopback function on
port.
Sets the specified content in
OAMPDU packet.
Enables or disables link monitor
function.
Sets the symbol period event
which is used for link monitor.
Sets the error frame.
Sets the period of error frame.
Sets error frame summary.