Zte ZXR10 3928A Hardware Installation Manual

Zxr10 3900a series; zxr10 3200a series. intelligent routing switch
Table of Contents

Advertisement

ZXR10 3900A/3200A Series
Intelligent Routing Switch
Hardware Installation Manual
Version 2.8.23.A
ZTE CORPORATION
ZTE Plaza, Keji Road South,
Hi-Tech Industrial Park,
Nanshan District, Shenzhen,
P. R. China
518057
Tel: (86) 755 26771900
Fax: (86) 755 26770801
URL: http://ensupport.zte.com.cn
E-mail: support@zte.com.cn

Advertisement

Table of Contents
loading

Summary of Contents for Zte ZXR10 3928A

  • Page 1 ZXR10 3900A/3200A Series Intelligent Routing Switch Hardware Installation Manual Version 2.8.23.A ZTE CORPORATION ZTE Plaza, Keji Road South, Hi-Tech Industrial Park, Nanshan District, Shenzhen, P. R. China 518057 Tel: (86) 755 26771900 Fax: (86) 755 26770801 URL: http://ensupport.zte.com.cn E-mail: support@zte.com.cn...
  • Page 2 The contents of this document are protected by copyright laws and international treaties. Any reproduction or distribution of this document or any portion of this document, in any form by any means, without the prior written consent of ZTE CORPO- RATION is prohibited.
  • Page 3: Table Of Contents

    Structure and Principle........9 Working Principles ............9 Hardware Structure ............10 ZXR10 3228A............10 ZXR10 3228A-EI ............11 ZXR10 3228A-FI............12 ZXR10 3252A............12 ZXR10 3928A............13 ZXR10 3928A-FI............14 ZXR10 3952A............14 ZXR10 3928A-PS............15 Units/Components Description ....... 17 Control and Switching Board ...........17 Line Interface Card ............20 FGEI ................20...
  • Page 4 550w Power Supply Unit for ZXR10 3928A-PS ....25 Installation and Debugging ......27 Equipment Installation ...........27 Desktop Installation ...........27 Cabinet Installation............28 Cable Installation ............29 Power Cable Installation ..........29 Console Cable Installation...........31 Network Cable Installation .........32 Optical Fiber Installation..........33 Power-on Procedure............34 RPS180 Backup Power ........
  • Page 5: About This Manual

    This chapter describes ZXR10 3900A/3200A Principle structure and principles. . Chapter 4 Units/Compo- This chapter describes ZXR10 3900A/3200A nents Description units/components. Chapter 5 Power Module This chapter describes structure and parameters of ZXR10 3900A/3200A power modules. Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 6 ZXR10 3900A/3200A(V2.8.23.A) Series Intelligent Routing Switch User Manual (Basic Configuration Volume) � ZXR10 3900A/3200A(V2.8.23.A) Series Intelligent Routing Switch User Manual (IPv4 Volume) � ZXR10 3900A/3200A(V2.8.23.A) Series Intelligent Routing Switch User Manual (IPv6 Volume) Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 7: Safety Introduction

    Safety precautions introduced in this manual are supplementary to the local safety codes. � ZTE bears no responsibility in case of universal safety oper- ation requirements violation and safety standards violation in designing, manufacturing and equipment usage. Safety Descriptions...
  • Page 8 ZXR10 3900A/3200A Series Hardware Installation Manual This page is intentionally blank. Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 9: System Overview

    (QoS) and to ensure the QoS and system security. ZXR10 3928A-PS Ethernet switch in ZXR10 3900A/3200A supports PoE. All of the 24 100Mpbs ports on this switch support PoE power supply, PoE in CISCO standard and IEEE 802.3af standard. The maximum one-port output is 15.4w.
  • Page 10: Functions

    � Open architecture design with greater upgrade capability Functions ZXR10 3900A contains the following four products: ZXR10 3928A, ZXR10 3928A-FI, ZXR10 3952A, ZXR10 3928A-PS. In the same way, ZXR10 3200A contains four products too: ZXR10 3228A, ZXR10 3228A-FI, 3228A-EI, ZXR10 3252A. All the above Ether- net switch series products use the same solution.
  • Page 11: Technical Features And Parameters

    3 ZXR10 3900A/3200A TECHNICAL FEATURES AND ABLE PARAMETERS Item Description Dimensions ZXR10 3228A: 43.6mm (height)×442mm (width)×280mm (depth) ZXR10 3228A-FI: 43.6mm (height)×442mm (width)×280mm (depth) ZXR10 3228A-EI: 43.6mm (height)×442mm (width)280mm (depth) ZXR10 3252A: 43.6mm (height)×442mm (width)×360mm (depth) Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 12 Power ZXR10 3228A: 20w consumption ZXR10 3228A-FI: 60w ZXR10 3228A-EI: 20W ZXR10 3252A: 35w ZXR10 3928A: 20w ZXR10 3928A-PS: 435w (main control bord:65w, MOP of PoE: 370w) ZXR10 3928A-FI: 60w ZXR10 3952A: 35w Reliability MTBF: >200000 hours MTTR: <30 minutes...
  • Page 13 ZXR10 3228A-FI: 13.98M ZXR10 3228A-EI: 13.98M ZXR10 3252A: 22.02M ZXR10 3928A: 13.98M ZXR10 3928A-PS: 13.98M ZXR10 3928A-FI: 13.98M ZXR10 3952A: 22.02M Routing table ZXR10 3900A/3200A: 12K entry MAC address ZXR10 3900A/3200A: 16K table depth Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 14 ZXR10 3900A/3200A Series Hardware Installation Manual This page is intentionally blank. Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 15: Structure And Principle

    Working Principles ZXR10 3900A/3200Aseries products are the box (L3) line-rate Eth- ernet switches developed by ZTE. This series switches adopt mod- ular design and have strong capability in service control and user management so as to provide networking solutions to convergence of enterprise network, IP MAN network and residential block.
  • Page 16: Hardware Structure

    The front panel of ZXR10 3228A is shown in Figure 2 ZXR10 3228A FRONT PANEL IGURE The back plane of AC power supply in ZXR10 3228A is shown in Figure 3 ZXR10 3228A B (AC) IGURE LANE Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 17: Zxr10 3228A-Ei

    The back plane of AC power supply in ZXR10 3228A—EI is shown Figure 6 ZXR10 3228A—EI B (AC) IGURE LANE The back plane of DC power supply in ZXR10 3228A—EI is shown Figure 7 ZXR10 3228A—EI B (DC) IGURE LANE Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 18: Zxr10 3228A-Fi

    SFP, supporting various gigabit modules meeting SFP standard. The front panel of ZXR10 3252A is shown in Figure 11 ZXR10 3252A FRONT PANEL IGURE The back plane of AC power supply in ZXR10 3252A is shown in Figure Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 19: Zxr10 3928A

    SFP, supporting various gigabit modules meeting SFP standard. The front panel of ZXR10 3928A is shown in Figure 14 ZXR10 3928A FRONT PANEL IGURE The back plane of AC power supply in ZXR10 3928A is shown in Figure 15 ZXR10 3928A B (AC) IGURE LANE...
  • Page 20: Zxr10 3928A-Fi

    100Mpbs modules meeting SFP standard. The front panel of ZXR10 3928A-FI is shown in Figure 17 ZXR10 3928A-FI FRONT PANEL IGURE The back plane of AC power supply in ZXR10 3928A-FI is shown Figure 18 ZXR10 3928A-FI B (AC) IGURE...
  • Page 21: Zxr10 3928A-Ps

    SFP standard. The front panel of ZXR10 3928A-PS is shown in Figure 23 ZXR10 3928A-PS FRONT PANEL IGURE The back plane of AC power supply in ZXR10 3928A-PS is shown Figure 24 ZXR10 3928A-PS B IGURE LANE Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 22 ZXR10 3900A/3200A Series Hardware Installation Manual This page is intentionally blank. Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 23: Units/Components Description

    3900A/3200A through the management terminal too. Man- agement interface supports 10/100Base-T. � 10/100Base-T Ethernet Interface ZXR10 3928A/3952A main control board supports 100 Base- TX, 10Base-T on CAT 5 cable. ZXR10 3228A-FI main control board supports 24/48 10/100Base-T Ethernet interfaces. The attributes are described in...
  • Page 24: Table 4 Attributes Of 10/100Base-T On Zxr10 3900A/3200A

    Off: The port speed is 10Mbps (100M port), the port speed is 1Gbps (Gigabit port) As ZXR10 3928A-PS supports various functions, double-color in- dicators are used. The board supports three display modes: rate display, duplex display and POE display. The indicator on fixed port is double-color indicator.
  • Page 25 No con- Green: Yellow: Mode nection full half duplex duplex Green Yellow flash: flash: link/ACT link/ACT POE Mode None Sub-card LINK No con- Green: nection con- nected No data Green flash: data are transmit- Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 26: Line Interface Card

    Slave Green: ter/Slave Master Line Interface Card FGEI There are two Gigabit Ethernet uplink electrical interfaces in SF-2800-2GE-2RJ45 mode on FGEI sub card, as shown in Figure 25 SF-2800-2GE-2RJ45 S FGEI IGURE CARD Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 27: Fgfi

    The gigabit electrical card contains two indicators: link activation indicator and link status indicator. 1. The link activation indicator flashes when data are sent or re- ceived. 2. The link status indicator is permanently on, when the link works well. Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 28: Fbfe

    There are two indicators on FBFE panel: ACT1 and ACT2. They correspond to two 100Mbps electrical interfaces. When the link works well, the indicator is on. When data are sent and received, the indicator flashes. Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 29: Power Module

    Active Power Supply ............23 Standby Power Supply ............25 3228A-EI Monitoring Interface ..........25 550w Power Supply Unit for ZXR10 3928A-PS ......25 Power Module Overview ZXR10 3900A/3200A series products provide built-in active power supply. This active power supports -48V DC power and 220V AC power.
  • Page 30 The AC power supply parameters of ZXR10 3228A are de- scribed as follows: Input Voltage: 90VAC-264VAC � Input Current: 0.6A � Frequency: 47-63Hz � Max Power Consumption: 37W � Line Voltage Waveform Deviation Factor (WDF)<5% � Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 31: Standby Power Supply

    The active power supply on ZXR10 3928A-PS is swappable 550W power supply. The power supply input interface is located on sys- tem back plane, supporting 200V AC. The AC power supply board on ZXR10 3928A-PS is shown in Figure Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 32 The AC power parameters on 3928A-PS are described as follows: 1. Input Voltage: single phase 100VAC ~240VAC 90-264Vac 2. Input Current: Max 7.2A 3. Frequency: 43Hz-67Hz 4. Max Power Consumption: 647W 5. Line Voltage Waveform Deviation Factor (WDF) <5% Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 33: Installation And Debugging

    ZXR10 3900A/3200A series switches can be placed on desks or fixed in 19-inch standard cabinets. Where, the 19-inch standard cabinet can be provided by the user. If ZTE's cabinet is to be used, you need refer to the 19-Inch Stan- dard Cabinet Installation Manual for cabinet installation. Desktop Installation...
  • Page 34: Cabinet Installation

    Figure 36 INSTALLING THE BRACKETS IGURE Bracket Screw Rack After the installation, push in the switch along the bracket, and fix the flanges to the cabinet, as shown in Figure Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 35: Cable Installation

    ZXR10 3900A/3200A AC power module and the other end is connected to the 220 VAC power socket. 2. DC power cable installation i. DC -48V power cable C-PWR-084 is shown in Figure 39 Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 36: Table 7 Dc Cables Two Ends Correspondence

    End B1 End B2 -48VGND -48V ii. DC standby power C-PWR-072 is shown in Figure 40 DC S C-PWR-072 IGURE TANDBY OWER The correspondence between two ends of DC cables are shown in Table Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 37: Console Cable Installation

    ERIAL ONSOLE ABLE TRUCTURE IAGRAM The serial console cable sequence is shown in Table 10 S ABLE ERIAL ONSOLE ABLE EQUENCE Cable Chroma- End B End A togram White Blue White orange White Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 38: Network Cable Installation

    The specific connection relationship is shown in Table 11 S RJ45 C ABLE TRAIGHT THROUGH ETWORK ABLE ABLE EQUENCE Cable Chroma- End B End A togram White-orange Orange White-green Green Blue White-blue White-brown Brown Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 39: Optical Fiber Installation

    The labels at two ends of the fiber must be clear. The meaning of the label must correctly reflect corresponding se- rial numbers and relationship between cabinets and between rows. Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 40: Power-On Procedure

    Turn on the power switch on the back plane of switch. 5. Power off procedure is shown as follows: i. Turn off the power switch on the back plane of switch. ii. Turn off the external power supply. Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 41: Rps180 Backup Power

    DC model supports standard 48V input. � Supporting 36V-72V wide range voltage input � AC model supports 110V/220V input. � Supporting 90V-264V wide range voltage input � Supporting 50Hz/60Hz voltage frequency input � 2. Output: Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 42: Technical Features And Parameters

    ZXR10 3900A/3200A Series Hardware Installation Manual Outputting standard 12V voltage, in the range of 11V-13V � Supporting ZTE switches such as 5100, 3900, 5900, which � have 12V backup power supply. Each output provides 15A loading current. � 15A load current is provided in total.
  • Page 43: Hardware Structure

    It contains two cards: power supply card and power distribu- tion card. � It provides two 12V DC power supply. � The input could be AC or standard -48V power supply. The front panel of ZXR10 RPS180 is shown in Figure Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 44: Boards

    CDPU CDPU is used to convert inputted -48V to the needed +12V DC power. 1. Standard three-core DC input socket is used. 2. The wide voltage range supports -36V—72V DC input voltage. Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 45: Lpdb

    ZXR10 RPS180 can be placed on desks or fixed in 19-inch standard cabinets. Where, the 19-inch standard cabinet can be provided by the user. If ZTE's cabinet is to be used, you need refer to the 19-Inch Stan- dard Cabinet Installation Manual for cabinet installation. Desktop Installation...
  • Page 46: Table 16 Dc Cables Two Ends Correspondence

    The B1 is connected to -48VGND of DC power sup- ply, and B2 is connected to -48V. The conductor labels are described in Table 17 L ABLE ABEL End B1 End B2 -48VGND -48V Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 47: Power-On Procedure

    Under the normal working environment of ZXR10 RPS180, the measurement values of temperature and humidity refer to those measured at 2 m above the floor and 0.4 m in front of the device (the Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 48 Turn on the power switch on the back plane of switch. 5. Power off procedure is shown as follows: i. Turn off the power switch on the back plane of switch. ii. Turn off the external power supply. Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 49: Figures

    Figure 12 ZXR10 3252A Back Plane (AC) ......13 Figure 13 ZXR10 3252A Back Plane (DC) ......13 Figure 14 ZXR10 3928A FRONT PANEL .........13 Figure 15 ZXR10 3928A Back Plane (AC) ......13 Figure 16 ZXR10 3928A Back Plane (DC) ......14 Figure 17 ZXR10 3928A-FI FRONT PANEL ......14 Figure 18 ZXR10 3928A-FI Back Plane (AC) ......14...
  • Page 50 Figure 44 ZXR10 RPS180 DC Model System Diagram....37 Figure 45 ZXR10 RPS180 Front Panel ........38 Figure 46 ZXR10 RPS180 Backplane........38 Figure 47 AC POWER CABLE..........40 Figure 48 DC cable C-PWR-084 ...........40 Figure 49 DC Standby Power Supply C-PWR-072....41 Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 51: Tables

    Table 4 Attributes of 10/100Base-T on ZXR10 3900A/3200A Main Control Board ..........18 Table 5 ZXR10 3900A/3200A Main Control Board Indicator Description ............18 Table 6 ZXR10 3928A-PS Main Control Board Indicator Description ............19 Table 7 DC cables Two Ends Correspondence ......30 Table 8 Label ..............30 Table 9 Two Ends Correspondence of DC Cables .....31...

Table of Contents