Zte ZXR10 5900 Series Hardware Manual

Zte ZXR10 5900 Series Hardware Manual

All gigabit-port intelligent routing switch
Hide thumbs Also See for ZXR10 5900 Series:
Table of Contents

Advertisement

ZXR10 5900/5200 Series
All Gigabit-Port Intelligent Routing Switch
Hardware Manual
Version 2.8.23A
ZTE CORPORATION
ZTE Plaza, Keji Road South,
Hi-Tech Industrial Park,
Nanshan District, Shenzhen,
P. R. China
518057
Tel: (86) 755 26771900
Fax: (86) 755 26770801
URL: http://ensupport.zte.com.cn
E-mail: support@zte.com.cn

Advertisement

Table of Contents
loading

Summary of Contents for Zte ZXR10 5900 Series

  • Page 1 ZXR10 5900/5200 Series All Gigabit-Port Intelligent Routing Switch Hardware Manual Version 2.8.23A ZTE CORPORATION ZTE Plaza, Keji Road South, Hi-Tech Industrial Park, Nanshan District, Shenzhen, P. R. China 518057 Tel: (86) 755 26771900 Fax: (86) 755 26770801 URL: http://ensupport.zte.com.cn E-mail: support@zte.com.cn...
  • Page 2 The contents of this document are protected by copyright laws and international treaties. Any reproduction or distribution of this document or any portion of this document, in any form by any means, without the prior written consent of ZTE CORPO- RATION is prohibited.
  • Page 3: Table Of Contents

    Contents About This Manual..........i Safety Introduction ...........1 Safety Introduction ............1 Safety Description ............1 System Overview ..........3 Product Overview ............3 Functions ..............4 Technical Features and Parameters ........5 Structure and Principle........9 Working Principles ............9 Hardware Structure ............10 ZXR10 5924/5224 .............10 ZXR10 5928/5228 .............11 ZXR10 5928-PS............12...
  • Page 4 Power Cable Installation ..........27 Console Cable Installation...........29 Network Cable Installation .........30 Optical Fiber Installation..........31 Power-on Procedure ............32 RPS180 Backup Power ........35 System Overview ............35 Product Overview ............35 Functions ..............35 Technical Features and Parameters ......36 Structure and Principle ...........36 Working Principles .............36 Hardware Structure ...........37 Cards................38 Power Conversion Card..........38...
  • Page 5: About This Manual

    This chapter describes ZXR10 5900/5200 Principle structure and principles. . Chapter 4 Units/Compo- This chapter describes ZXR10 5900/5200 nents Description units/components. Chapter 5 Power Module This chapter describes structure and parameters of ZXR10 5900/5200 power modules. Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 6 ZXR10 Router/Ethernet Switch Command Manual — Protocol Stack I � ZXR10 Router/Ethernet Switch Command Manual — Protocol Stack II � ZXR10 Router/Ethernet Switch Command Manual — Protocol Stack III � ZXR10 Router/Ethernet Switch Information Manual Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 7: Safety Introduction

    Safety precautions introduced in this manual are supplementary to the local safety codes. � ZTE bears no responsibility in case of universal safety oper- ation requirements violation and safety standards violation in designing, manufacturing and equipment usage. Safety Description...
  • Page 8 ZXR10 5900/5200 Series Hardware Manual This page is intentionally blank. Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 9: System Overview

    Product Overview ZXR10 5900/5200 series products are gigabit Ethernet routing switches developed by ZTE independently. The switches can be both used in convergence layer of MAN and used as L3 switch at large-size enterprise network, campus network, and used as ac- cess switch for desktop access from gigabit Ethernet network, as well as used in data center which requires gigabit bandwidth (e.g.
  • Page 10: Functions

    � PIM-SM, MSDP 5. ACL Supporting basic ACL, extended ACL, L2 ACL and hybrid � Supporting ACL time range limit � Supporting 802.1p � Supporting queue schedule mode � Supporting traffic monitoring � Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 11: Technical Features And Parameters

    ZXR10 5252: 43.6mm (height)×442mm (width)×400mm (depth) ZXR10 5924: 43.6mm (height)×442mm (width)×280mm (depth) ZXR10 5928: 43.6mm (height)×442mm (width)×360mm (depth) ZXR10 5928-FI: 43.6mm (height)×442mm (width)×320mm (depth) ZXR10 5952: 43.6mm (height)×442mm (width)×400mm (depth) ZXR10 5928-PS: 43.6mm (height)×442mm (width)×400mm (depth) Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 12 Relative humidity: 10% to 90%, non-condensing humidity Memory size ZXR10 5224: 128M ZXR10 5228: 128M ZXR10 5228-FI: 128M ZXR10 5252: 128M ZXR10 5924: 256M ZXR10 5928: 256M ZXR10 5928-FI: 256M ZXR10 5952: 256M ZXR10 5928-PS: 256M Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 13 ZXR10 5924: 36M ZXR10 5928: 96M ZXR10 5928-FI: 96M ZXR10 5952: 132M ZXR10 5928-PS: 96M ZXR10 5900: 20K Routing table entry ZXR10 5200: 2.5K MAC address ZXR10 5900: 16K table depth ZXR10 5200: 8K Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 14 ZXR10 5900/5200 Series Hardware Manual This page is intentionally blank. Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 15: Structure And Principle

    Working Principles ZXR10 5900/5200 series products are the box line-rate Ethernet switches developed by ZTE. This series switches adopt modular design and have strong capability in service control and user man- agement so as to provide networking solutions to convergence of enterprise network, IP MAN network and residential block.
  • Page 16: Hardware Structure

    2 ZXR10 5924 FRONT PANEL IGURE The front panel of ZXR10 5224 is shown in Figure 3 ZXR10 5224 FRONT PANEL IGURE The backplane of AC power in ZXR10 5924 is shown in Figure Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 17: Zxr10 5928/5228

    10G stacking electrical interfaces. The front panel of ZXR10 5928 is shown in Figure 8 ZXR10 5928 FRONT PANEL IGURE The front panel of ZXR10 5228 is shown in Figure 9 ZXR10 5228 FRONT PANEL IGURE Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 18: Zxr10 5928-Ps

    There are 4 10G Ethernet Interface board slots on the backplane. All 4 slots can be configured with 10G Ethernet optical interfaces or 10G stacking electrical interfaces. The front panel of ZXR10 5928-FI is shown in Figure Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 19: Zxr10 5952/5252

    The front panel of ZXR10 5952 is shown in Figure 18 ZXR10 5952 FRONT PANEL IGURE The front panel of ZXR10 5252 is shown in Figure 19 ZXR10 5252 FRONT PANEL IGURE Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 20 The backplane of AC power in ZXR10 5952/5252 is shown in Figure 20 ZXR10 5952/5252 B (AC) IGURE ACKPLANE The backplane of DC power in ZXR10 5952/5252 is shown in Figure 21 ZXR10 5952/5252 B (DC) IGURE ACKPLANE Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 21: Units/Components Description

    � 10/100/1000 Base-T Ethernet Interface ZXR10 5900/5200 main control board supports 24~48 10/100/1000 Base-T Ethernet interfaces and 1000Base-T, 100 Base-TX, 10Base-T on CAT 5. The attributes are described in Table Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 22: Table 4 Zxr10 5900/5200 Attributes Of 10/100/1000Base-T On Main Control Board

    POE display. These indicators on port are double-color LEDs. There are five indicators: mode, RUN, PWR, RPS, M/S. The indi- cator functions are shown in Table Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 23 None 10G Sub-card LINK Off: No Green: connection connected Off: No Green flash: data data are transmitted NO DC Flash: board works well None Perma- nently on: AC works well Flash: Power alarm Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 24: Line Interface Card

    Four cards can be configured in ZXR10 5928/5228/5928-FI/5228-FI/5952/5252 system as maximum. The SC-1XGS-CX4 panel is shown in Figure Panel 22 SC-1XGS-CX4 P IGURE ANEL SC-1XGS-CX4 card interface attributes are shown in Table Interface Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 25: Sc-1Xgl-Xfp

    10G Ethernet XFP optical interface, which is used for uplink cascading. Four cards can be configured in ZXR10 5928/5228/5928-FI/5228-FI /5952/5252 system as maximum, providing four 10G Ethernet XFP optical interfaces. The SC-1XGL-XFP panel is shown in Figure Panel Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 26: Table 10 Sc-1Xgl-Xfp Indicators Functions

    10 SC-1XGL-XFP INDICATORS FUNCTIONS ABLE Indicators Functions LINK/ACT On: A link is established on the interface Off: This interface is not connected to others. Flash: Packets are being transmitted or received on the interface. Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 27: Power Module

    48V DC and 220V AC. The AC power board on ZXR10 5900/5200 is shown in Figure 24 ZXR10 5900/5200 AC P IGURE OWER UPPLY NTERFACE The DC power board onZXR10 5900/5200 is shown in Figure Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 28 � Line Voltage Waveform Deviation Factor (WDF)<5% � The DC power parameters of ZXR10 5224 are described as follows: Input Voltage: single phase 100VAC ~240VAC � Input Current: 1.0A � Frequency: 50Hz-60Hz � Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 29: Zxr10 5900/5200 Standby Power

    200V AC. The AC power supply board on ZXR10 5928-PS is shown in Figure 27 ZXR10 5928-PS AC I IGURE NTERFACE The AC power parameters on 5928-PS are described as follows: Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 30 ZXR10 5900/5200 Series Hardware Manual 1. Input Voltage: single phase 90VAC ~264VAC 2. Input Current: Max 7.2A 3. Frequency: 43Hz-67Hz 4. Max Power Consumption: 647W 5. Line Voltage Waveform Deviation Factor (WDF) <5% Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 31: Installation And Debugging

    ZXR10 5900/5200 series switches can be placed on desks or fixed in 19-inch standard cabinets. Where, the 19-inch standard cabinet can be provided by the user. If ZTE’s cabinet is to be used, you need refer to the 19-Inch Stan- dard Cabinet Installation Manual for cabinet installation. Desktop Installation...
  • Page 32 30 INSTALLING THE BRACKETS IGURE Bracket Screw Rack After the installation, push in the switch along the bracket, and fix the flanges to the cabinet, as shown in Figure 31 (taking ZXR10 5224 as example). Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 33: Cable Installation

    One end of the AC power cable connects the AC power socket of ZXR10 5900/5200 AC power module and the other end con- nects the 220V AC power socket. 2. DC power cable installation i. DC -48V power cable C-PWR-084 is shown in Figure Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 34: Table 11 Two Ends Correspondence Of Dc Cables

    End B2 End B1 -48VGND -48V ii. DC standby power C-PWR-072 is shown in Figure 34 DC S C-PWR-072 IGURE TANDBY OWER The correspondence between two ends of DC cables are shown in Table Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 35: Console Cable Installation

    IGURE ERIAL ONSOLE ABLE TRUCTURE IAGRAM The serial console cable sequence is shown in Table 14 S ABLE ERIAL ONSOLE ABLE EQUENCE Cable Chroma- End B End A togram White Blue White orange Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 36: Network Cable Installation

    � Straight-through network cable RJ45: the cable connection re- lationship is in the one-to-one correspondence at both ends. The specific connection relationship is shown in Table Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 37: Optical Fiber Installation

    Note that there are TX, RX on the panel. Do not mix them. There are two kinds of fibers: single-mode fiber and multi-mode fibers. Users can use them according to practical conditions. Six fibers are shown in Table Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 38: Power-On Procedure

    15 days. 2. Check whether the power cables and the cables are connected correctly and reliably or not. 3. Check other hardware. 4. Power on the ZXR10 5900/5200 in the following steps: Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 39 Turn on the power switch on the back plane of switch. 5. Power off procedure is shown as follows: i. Turn off the power switch on the back plane of switch. ii. Turn off the external power supply. Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 40 ZXR10 5900/5200 Series Hardware Manual This page is intentionally blank. Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 41: Rps180 Backup Power

    Supporting 50Hz/60Hz voltage frequency input � 2. Output: Outputting standard 12V voltage, in the range of 11V-13V � Supporting ZTE switches such as 5100, 3900, 5900, which � have standby 12V power supply. Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 42: Technical Features And Parameters

    1. The DC model contains power supply distribution card LPDB and DC power card CDPU. CDPU corresponds to convert input -48V DC voltage to +12V available DC power. LPDB corresponds to output +12V power in three outputs and maintain them. Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 43: Hardware Structure

    It contains two cards: power supply card and power distribu- tion card. � It provides two 12V DC power supply. � The input could be AC or standard -48V power supply. The front panel of ZXR10 RPS180 is shown in Figure Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 44: Cards

    CDPU CDPU is used to convert inputted -48V to the needed +12V DC power. 1. Standard three-core DC input socket is used. 2. The wide voltage range supports -36V—72V DC input voltage. Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 45: Lpdb

    ZXR10 RPS180 can be placed on desks or fixed in 19-inch standard cabinets. Where, the 19-inch standard cabinet can be provided by the user. If ZTE’s cabinet is to be used, you need refer to the 19-Inch Stan- dard Cabinet Installation Manual for cabinet installation. Desktop Installation...
  • Page 46: Table 20 Dc Cables Two Ends Correspondence

    The B1 is connected to -48VGND of DC power sup- ply, and B2 is connected to -48V. The conductor labels are described in Table 21 L ABLE ABEL End B1 End B2 -48VGND -48V Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 47: Power-On Procedure

    Under the normal working environment of ZXR10 RPS180, the measurement values of temperature and humidity refer to those measured at 2 m above the floor and 0.4 m in front of the device (the Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 48 Turn on the power switch on the back plane of switch. 5. Power off procedure is shown as follows: i. Turn off the power switch on the back plane of switch. ii. Turn off the external power supply. Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 49: Figures

    Figure 28 Desktop Installation ..........25 Figure 29 INSTALLING THE FLANGES ........26 Figure 30 INSTALLING THE BRACKETS .........26 Figure 31 FIXING THE SWITCH..........27 Figure 32 AC POWER CABLE..........27 Figure 33 DC cable C-PWR-084 ...........28 Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 50 Figure 38 ZXR10 RPS180 DC Model System Diagram....37 Figure 39 ZXR10 RPS180 Front Panel ........38 Figure 40 ZXR10 RPS180 Backplane........38 Figure 41 AC POWER CABLE..........40 Figure 42 DC cable C-PWR-084 ...........40 Figure 43 DC Standby Power Supply C-PWR-072....41 Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 51: Tables

    Table 19 ZXR10 RPS180 TECHNICAL FEATURES AND PARAMETERS ............36 Table 20 DC cables Two Ends Correspondence .......40 Table 21 Label..............40 Table 22 DC cables Two Ends Correspondence .......41 Table 23 TEMPERATURE AND HUMIDITY........41 Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 52 ZXR10 5900/5200 Series Hardware Manual This page is intentionally blank. Confidential and Proprietary Information of ZTE CORPORATION...
  • Page 53: List Of Glossary

    SNMP - Simple Network Management Protocol SP - Strict Priority SSH - Secure Shell STP - Spanning Tree Protocol VLAN - Virtual Local Area Network VRRP - Virtual Router Redundancy Protocol WRR - Weighted Round Robin Confidential and Proprietary Information of ZTE CORPORATION...