Page 1
ZXR10 5900/5200 Series All Gigabit-Port Intelligent Routing Switch Hardware Manual Version 2.8.23A ZTE CORPORATION ZTE Plaza, Keji Road South, Hi-Tech Industrial Park, Nanshan District, Shenzhen, P. R. China 518057 Tel: (86) 755 26771900 Fax: (86) 755 26770801 URL: http://ensupport.zte.com.cn E-mail: support@zte.com.cn...
Page 2
The contents of this document are protected by copyright laws and international treaties. Any reproduction or distribution of this document or any portion of this document, in any form by any means, without the prior written consent of ZTE CORPO- RATION is prohibited.
This chapter describes ZXR10 5900/5200 Principle structure and principles. . Chapter 4 Units/Compo- This chapter describes ZXR10 5900/5200 nents Description units/components. Chapter 5 Power Module This chapter describes structure and parameters of ZXR10 5900/5200 power modules. Confidential and Proprietary Information of ZTE CORPORATION...
Page 6
ZXR10 Router/Ethernet Switch Command Manual — Protocol Stack I � ZXR10 Router/Ethernet Switch Command Manual — Protocol Stack II � ZXR10 Router/Ethernet Switch Command Manual — Protocol Stack III � ZXR10 Router/Ethernet Switch Information Manual Confidential and Proprietary Information of ZTE CORPORATION...
Safety precautions introduced in this manual are supplementary to the local safety codes. � ZTE bears no responsibility in case of universal safety oper- ation requirements violation and safety standards violation in designing, manufacturing and equipment usage. Safety Description...
Page 8
ZXR10 5900/5200 Series Hardware Manual This page is intentionally blank. Confidential and Proprietary Information of ZTE CORPORATION...
Product Overview ZXR10 5900/5200 series products are gigabit Ethernet routing switches developed by ZTE independently. The switches can be both used in convergence layer of MAN and used as L3 switch at large-size enterprise network, campus network, and used as ac- cess switch for desktop access from gigabit Ethernet network, as well as used in data center which requires gigabit bandwidth (e.g.
Working Principles ZXR10 5900/5200 series products are the box line-rate Ethernet switches developed by ZTE. This series switches adopt modular design and have strong capability in service control and user man- agement so as to provide networking solutions to convergence of enterprise network, IP MAN network and residential block.
2 ZXR10 5924 FRONT PANEL IGURE The front panel of ZXR10 5224 is shown in Figure 3 ZXR10 5224 FRONT PANEL IGURE The backplane of AC power in ZXR10 5924 is shown in Figure Confidential and Proprietary Information of ZTE CORPORATION...
10G stacking electrical interfaces. The front panel of ZXR10 5928 is shown in Figure 8 ZXR10 5928 FRONT PANEL IGURE The front panel of ZXR10 5228 is shown in Figure 9 ZXR10 5228 FRONT PANEL IGURE Confidential and Proprietary Information of ZTE CORPORATION...
There are 4 10G Ethernet Interface board slots on the backplane. All 4 slots can be configured with 10G Ethernet optical interfaces or 10G stacking electrical interfaces. The front panel of ZXR10 5928-FI is shown in Figure Confidential and Proprietary Information of ZTE CORPORATION...
The front panel of ZXR10 5952 is shown in Figure 18 ZXR10 5952 FRONT PANEL IGURE The front panel of ZXR10 5252 is shown in Figure 19 ZXR10 5252 FRONT PANEL IGURE Confidential and Proprietary Information of ZTE CORPORATION...
Page 20
The backplane of AC power in ZXR10 5952/5252 is shown in Figure 20 ZXR10 5952/5252 B (AC) IGURE ACKPLANE The backplane of DC power in ZXR10 5952/5252 is shown in Figure 21 ZXR10 5952/5252 B (DC) IGURE ACKPLANE Confidential and Proprietary Information of ZTE CORPORATION...
� 10/100/1000 Base-T Ethernet Interface ZXR10 5900/5200 main control board supports 24~48 10/100/1000 Base-T Ethernet interfaces and 1000Base-T, 100 Base-TX, 10Base-T on CAT 5. The attributes are described in Table Confidential and Proprietary Information of ZTE CORPORATION...
POE display. These indicators on port are double-color LEDs. There are five indicators: mode, RUN, PWR, RPS, M/S. The indi- cator functions are shown in Table Confidential and Proprietary Information of ZTE CORPORATION...
Page 23
None 10G Sub-card LINK Off: No Green: connection connected Off: No Green flash: data data are transmitted NO DC Flash: board works well None Perma- nently on: AC works well Flash: Power alarm Confidential and Proprietary Information of ZTE CORPORATION...
Four cards can be configured in ZXR10 5928/5228/5928-FI/5228-FI/5952/5252 system as maximum. The SC-1XGS-CX4 panel is shown in Figure Panel 22 SC-1XGS-CX4 P IGURE ANEL SC-1XGS-CX4 card interface attributes are shown in Table Interface Confidential and Proprietary Information of ZTE CORPORATION...
10G Ethernet XFP optical interface, which is used for uplink cascading. Four cards can be configured in ZXR10 5928/5228/5928-FI/5228-FI /5952/5252 system as maximum, providing four 10G Ethernet XFP optical interfaces. The SC-1XGL-XFP panel is shown in Figure Panel Confidential and Proprietary Information of ZTE CORPORATION...
10 SC-1XGL-XFP INDICATORS FUNCTIONS ABLE Indicators Functions LINK/ACT On: A link is established on the interface Off: This interface is not connected to others. Flash: Packets are being transmitted or received on the interface. Confidential and Proprietary Information of ZTE CORPORATION...
48V DC and 220V AC. The AC power board on ZXR10 5900/5200 is shown in Figure 24 ZXR10 5900/5200 AC P IGURE OWER UPPLY NTERFACE The DC power board onZXR10 5900/5200 is shown in Figure Confidential and Proprietary Information of ZTE CORPORATION...
Page 28
� Line Voltage Waveform Deviation Factor (WDF)<5% � The DC power parameters of ZXR10 5224 are described as follows: Input Voltage: single phase 100VAC ~240VAC � Input Current: 1.0A � Frequency: 50Hz-60Hz � Confidential and Proprietary Information of ZTE CORPORATION...
200V AC. The AC power supply board on ZXR10 5928-PS is shown in Figure 27 ZXR10 5928-PS AC I IGURE NTERFACE The AC power parameters on 5928-PS are described as follows: Confidential and Proprietary Information of ZTE CORPORATION...
Page 30
ZXR10 5900/5200 Series Hardware Manual 1. Input Voltage: single phase 90VAC ~264VAC 2. Input Current: Max 7.2A 3. Frequency: 43Hz-67Hz 4. Max Power Consumption: 647W 5. Line Voltage Waveform Deviation Factor (WDF) <5% Confidential and Proprietary Information of ZTE CORPORATION...
ZXR10 5900/5200 series switches can be placed on desks or fixed in 19-inch standard cabinets. Where, the 19-inch standard cabinet can be provided by the user. If ZTE’s cabinet is to be used, you need refer to the 19-Inch Stan- dard Cabinet Installation Manual for cabinet installation. Desktop Installation...
Page 32
30 INSTALLING THE BRACKETS IGURE Bracket Screw Rack After the installation, push in the switch along the bracket, and fix the flanges to the cabinet, as shown in Figure 31 (taking ZXR10 5224 as example). Confidential and Proprietary Information of ZTE CORPORATION...
One end of the AC power cable connects the AC power socket of ZXR10 5900/5200 AC power module and the other end con- nects the 220V AC power socket. 2. DC power cable installation i. DC -48V power cable C-PWR-084 is shown in Figure Confidential and Proprietary Information of ZTE CORPORATION...
End B2 End B1 -48VGND -48V ii. DC standby power C-PWR-072 is shown in Figure 34 DC S C-PWR-072 IGURE TANDBY OWER The correspondence between two ends of DC cables are shown in Table Confidential and Proprietary Information of ZTE CORPORATION...
IGURE ERIAL ONSOLE ABLE TRUCTURE IAGRAM The serial console cable sequence is shown in Table 14 S ABLE ERIAL ONSOLE ABLE EQUENCE Cable Chroma- End B End A togram White Blue White orange Confidential and Proprietary Information of ZTE CORPORATION...
� Straight-through network cable RJ45: the cable connection re- lationship is in the one-to-one correspondence at both ends. The specific connection relationship is shown in Table Confidential and Proprietary Information of ZTE CORPORATION...
Note that there are TX, RX on the panel. Do not mix them. There are two kinds of fibers: single-mode fiber and multi-mode fibers. Users can use them according to practical conditions. Six fibers are shown in Table Confidential and Proprietary Information of ZTE CORPORATION...
15 days. 2. Check whether the power cables and the cables are connected correctly and reliably or not. 3. Check other hardware. 4. Power on the ZXR10 5900/5200 in the following steps: Confidential and Proprietary Information of ZTE CORPORATION...
Page 39
Turn on the power switch on the back plane of switch. 5. Power off procedure is shown as follows: i. Turn off the power switch on the back plane of switch. ii. Turn off the external power supply. Confidential and Proprietary Information of ZTE CORPORATION...
Page 40
ZXR10 5900/5200 Series Hardware Manual This page is intentionally blank. Confidential and Proprietary Information of ZTE CORPORATION...
Supporting 50Hz/60Hz voltage frequency input � 2. Output: Outputting standard 12V voltage, in the range of 11V-13V � Supporting ZTE switches such as 5100, 3900, 5900, which � have standby 12V power supply. Confidential and Proprietary Information of ZTE CORPORATION...
1. The DC model contains power supply distribution card LPDB and DC power card CDPU. CDPU corresponds to convert input -48V DC voltage to +12V available DC power. LPDB corresponds to output +12V power in three outputs and maintain them. Confidential and Proprietary Information of ZTE CORPORATION...
It contains two cards: power supply card and power distribu- tion card. � It provides two 12V DC power supply. � The input could be AC or standard -48V power supply. The front panel of ZXR10 RPS180 is shown in Figure Confidential and Proprietary Information of ZTE CORPORATION...
CDPU CDPU is used to convert inputted -48V to the needed +12V DC power. 1. Standard three-core DC input socket is used. 2. The wide voltage range supports -36V—72V DC input voltage. Confidential and Proprietary Information of ZTE CORPORATION...
ZXR10 RPS180 can be placed on desks or fixed in 19-inch standard cabinets. Where, the 19-inch standard cabinet can be provided by the user. If ZTE’s cabinet is to be used, you need refer to the 19-Inch Stan- dard Cabinet Installation Manual for cabinet installation. Desktop Installation...
The B1 is connected to -48VGND of DC power sup- ply, and B2 is connected to -48V. The conductor labels are described in Table 21 L ABLE ABEL End B1 End B2 -48VGND -48V Confidential and Proprietary Information of ZTE CORPORATION...
Under the normal working environment of ZXR10 RPS180, the measurement values of temperature and humidity refer to those measured at 2 m above the floor and 0.4 m in front of the device (the Confidential and Proprietary Information of ZTE CORPORATION...
Page 48
Turn on the power switch on the back plane of switch. 5. Power off procedure is shown as follows: i. Turn off the power switch on the back plane of switch. ii. Turn off the external power supply. Confidential and Proprietary Information of ZTE CORPORATION...
Figure 28 Desktop Installation ..........25 Figure 29 INSTALLING THE FLANGES ........26 Figure 30 INSTALLING THE BRACKETS .........26 Figure 31 FIXING THE SWITCH..........27 Figure 32 AC POWER CABLE..........27 Figure 33 DC cable C-PWR-084 ...........28 Confidential and Proprietary Information of ZTE CORPORATION...
Page 50
Figure 38 ZXR10 RPS180 DC Model System Diagram....37 Figure 39 ZXR10 RPS180 Front Panel ........38 Figure 40 ZXR10 RPS180 Backplane........38 Figure 41 AC POWER CABLE..........40 Figure 42 DC cable C-PWR-084 ...........40 Figure 43 DC Standby Power Supply C-PWR-072....41 Confidential and Proprietary Information of ZTE CORPORATION...
Table 19 ZXR10 RPS180 TECHNICAL FEATURES AND PARAMETERS ............36 Table 20 DC cables Two Ends Correspondence .......40 Table 21 Label..............40 Table 22 DC cables Two Ends Correspondence .......41 Table 23 TEMPERATURE AND HUMIDITY........41 Confidential and Proprietary Information of ZTE CORPORATION...
Page 52
ZXR10 5900/5200 Series Hardware Manual This page is intentionally blank. Confidential and Proprietary Information of ZTE CORPORATION...