Error Messages In Gp-Gl Command Mode - GRAPHTEC FC8000 Series User Manual

Cutting pro
Hide thumbs Also See for FC8000 Series:
Table of Contents

Advertisement

Symptom
•Characters are deformed.
•Complex drawings are deformed.
•The starting and end points of cutting do Coordinate points are
not match.
Error Messages in
Error
LCD Display
Displayed
E02001
E02004
E02005
Cause
The STEP PASS setting is
set too high.
incorrectly specifed.
The media backing is too
fimsy.
Blade rotation is not smooth. Check that there is no dirt in the blade.
GP-GL Command Mode
Cause
The plotter received an
unrecognizable command.
• Noise came in when the
computer was turned on.
• The software confguration
regarding the output device has
been changed.
• The plotter's interface conditions
have changed.
A command was received
containing numeric parameters
that exceed that command's
permissible range.
• The software confguration
regarding the output device has
been changed.
• The plotter's interface conditions
have changed.
An error occurred in the receipt of
data within the interface.
• The software confguration
regarding the output device has
been changed.
• The plotter's interface conditions
have changed.
13-6
Solution
Lower the STEP PASS setting.
Check the coordinate data by plotting it
with a pen.
Switch to a media with a stronger
backing.
Solution
Press the [ENTER] key.
Confgure to drive the plotter from
the menu of the software.
Reset the interface settings of the
software.
Reset the interface settings of the
plotter.
Confgure to drive the plotter from
the menu of the software.
Reset the interface settings of the
software.
Reset the interface settings of the
plotter.
Confgure to drive the plotter from
the menu of the software.
Reset the interface settings of the
software.
Reset the interface settings of the
plotter.

Hide quick links: