MARK TYPE 2
MARK TYPE2 is used when you would like to use as much area
possible on the media as cutting area. The registration mark is
inside the cutting area, so set the MARK DISTANCE so plotted
image will not be mistaken as a registration mark. Also, you can not
cut close to the registration mark (right image).
Do not plot image in the area where the sensor moves to scan
the registration mark when the MARK DISTANCE is not used so it
will not read the image while detecting the registration mark (left
image).
Supplement
l
Create the registration mark as a plotting data with the application software. Registration marks generated by the application software cannot
be used.
l
Create the registration mark in accordance with following conditions.
· Thickness of the line is between 0.3 and 1.0 mm.
· Size of the registration mark is between 5 and 20 mm (see "Setting Registration Mark Size"
· Use pattern 1 or pattern 2 for the shape of the registration mark.
· Create the registration mark with single line, and specify the thickness of line to necessary thickness. Double line cannot be used.
· Center of the line for the registration mark is the reference.

Scan Range Necessary to Detect the Registration Mark

The
range of tool carriage and media movement needed to scan the registration mark is as following.
MARK TYPE1
a
= 6 mm
Registration scanning area
area necessary to scan the registration mark when the mark distance is set is as following:

MARK TYPE2

Cutting area
For 3POINTS
MARK TYPE2
a
a = 6
mm
scanning area
a
a = 6 mm
5-3
Supplement
l
Left fgure is for 4POINTS. Number of the
registration mark will be different for the
2POINTS and 3 POINTS, but the shape of the
registration mark will be same.
See "Setting Shape (Pattern) of Registration
l
Mark"
P .5-9
to change the shape (pattern)
of the registration mark.
See "Setting Mark Distance"
l
setting MARK DISTANCE.
P .5-11
).
For 4POINTS
TYPE1
MARK TYPE2
a
a = 6
mm
scanning area
Registration scanning
P .5-12
for
a
area

Hide quick links: