Outline of Manual Position Adjust

With manual position adjust, tilt of the axes are adjusted using the 2POINTS, 3POINTS, or 4POINTS
adjustment marks (grits or registration marks) as a standard. The distance between each points can also be
entered to adjust the distance.
Use magnifier or light pointer as a tool to match each points.
Use the media with prints (adjustment marks such as grits or registration marks) necessary to get XY axes
and origin point.
Setting of Mark Scan Mode and Number of
T o
perform the AXIS ALIGNMENT , set the MARK SCAN MODE to "AXISALIGNMENT".
Select the number of the registration marks (adjustment marks) from 2POINTS, 3POINTS, or 4POINTS when the
MARK SCAN MODE is set to "AXISALIGNMENT".Position of each adjustment marks are as following.
2POINTS
4POINTS
Fourth point
Operation
See "Setting MARK SCAN Mode and Numbers"
Second point
First point or
origin point
Second point
First point or
origin point
Third point
Adjustment Marks
3POINTS
Third point
for how to operate.
P .5-6
6-2
Second point
First point or
origin point