Map 1529: There Is A Bulk Power Assembly (Bpa) Communication Failure - IBM pSeries 670 Service Manual

Hide thumbs Also See for pSeries 670:
Table of Contents

Advertisement

MAP 1529: There Is A Bulk Power Assembly (BPA) Communication
Failure
Step 1529-1
Check the position of the on/off switch on the BPRs.
Is the switch in the ON position (to the left)?
Set the switch to the ON position (to the left), and go to "MAP 0410: Repair Checkout" in the
NO
RS/6000 and Eserver pSeries Diagnostic Information for Multiple Bus Systems.
YES
Go to "Step 1529-2".
Step 1529-2
Note: Read the Danger and Caution notices under "Safety Notices" on page xi before continuing with this
procedure.
1.
Prepare a multimeter to measure up to 600 V ac.
2. Use the multimeter to measure the ac voltage at the following test points on the face plate of the BPA
that is not referenced by the error code that sent you to this MAP:
v Phase A and phase B
v Phase B and phase C
v Phase C and phase A
Are all the readings greater than 180 V ac?
NO
Go to "Step 1529-3" on page 164.
YES
Exchange the following FRUs one at a time:
1. BPR 1, that is connected to the IBF not referenced in the error code that brought you to this
MAP. Follow all steps in the removal and replacement procedures for "Bulk Power Regulator
(BPR)" on page 783.
2. BPR 2, that is connected to the IBF not referenced in the error code that brought you to this
MAP. Follow all steps in the removal and replacement procedures for "Bulk Power Regulator
(BPR)" on page 783.
3. BPR 3, that is connected to the IBF not referenced in the error code that brought you to this
MAP. Follow all steps in the removal and replacement procedures for "Bulk Power Regulator
(BPR)" on page 783.
4. BPC on the other side not referenced by the error code that sent you to this MAP. Follow all
steps in the removal and replacement procedures for "Bulk Power Controller (BPC)" on
page 784.
5. BPE on the other side not referenced by the error code that sent you to this MAP. Follow all
steps in the removal and replacement procedures for "Bulk Power Enclosure (BPE)" on
page 787.
After each FRU is exchanged, is the error code that sent you to this MAP still reported?
The problem has been corrected. Go to "MAP 0410: Repair Checkout" in the RS/6000 and
NO
Eserver pSeries Diagnostic Information for Multiple Bus Systems
YES
Replace the next FRU on the list. If all FRUs on the list have been replaced, call for
support.
Chapter 3. Maintenance Analysis Procedures