Error Code Description
1025 1B17 Problem with fan 1 in fourth I/O subsystem in
second rack (I/O subsystem 8)
1025 1B27 Problem with fan 2 in fourth I/O subsystem in
second rack (I/O subsystem 8)
1025 1C06 Loss of airflow in fourth I/O subsystem in second
rack (I/O subsystem 8),
location: U2.19
1025 6014 Overcurrent or overvoltage problem with 3.3V in
fourth I/O subsystem in second rack (I/O
subsystem 8)
1025 6024 Overcurrent or overvoltage problem with 5.0V in
fourth I/O subsystem in second rack (I/O
subsystem 8)
1025 6034 Overcurrent or overvoltage problem with 2.5V in
fourth I/O subsystem in second rack (I/O
subsystem 8)
1025 6044 Overcurrent or overvoltage problem with 12.0V
in fourth I/O subsystem in second rack (I/O
subsystem 8)
1025 6054 Overcurrent or overvoltage problem with -12.0V
in fourth I/O subsystem in second rack (I/O
subsystem 8)
1025 6814 Overcurrent or overvoltage problem with 3.3V in
fourth I/O subsystem in second rack (I/O
subsystem 8)
1025 6824 Overcurrent or overvoltage problem with 5.0V in
fourth I/O subsystem in second rack (I/O
subsystem 8)
1025 6834 Overcurrent or overvoltage problem with 2.5V in
fourth I/O subsystem in second rack (I/O
subsystem 8)
1025 6844 Overcurrent or overvoltage problem with 12.0V
in fourth I/O subsystem in second rack (I/O
subsystem 8)
1025 6854 Overcurrent or overvoltage problem with -12.0V
in fourth I/O subsystem in second rack (I/O
subsystem 8)
1025 7017 Problem with fan 3 in fourth I/O subsystem in
second I/O subsystem in second rack (I/O
subsystem 8)
1025 7027 Problem with fan 4 in fourth I/O subsystem in
second rack (I/O subsystem 8)
408
Eserver pSeries 670 Service Guide
Action/
Possible Failing FRU
1. DCA-1
Location: U2.19-V1
2. Fan 1
Location: U2.19-F1
1. DCA-2
Location: U2.19-V2
2. Fan 2
Location: U2.19-F2
Go to "MAP 1527: An Airflow Loss Has Been
Detected" on page 160.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
1. DCA-1
Location: U2.19-V1
2. Fan 3
Location: U2.19-F3
1. DCA-2
Location: U2.19-V2
2. Fan 4
Location: U2.19-F4

Advertisement