Step 152h-30
Turn on the power.
Step 152h-31
Did the system stop with the same error code as recorded in "Step 152h-1" on page 206?
Yes
The card just reinserted is defective. Replace it. This ends the procedure.
Return the system to its original configuration.
Go to "MAP 0410: Repair Checkout" in the RS/6000 and Eserver pSeries Diagnostic Information
for Multiple Bus Systems.
No
Go to "Step 152h-32".
Step 152h-32
Have all the cards listed in "Step 152h-25" on page 209 been reinserted?
Yes
The symptom has changed. This ends the procedure.
Return the system to its original configuration.
Go to "MAP 0410: Repair Checkout" in the RS/6000 and Eserver pSeries Diagnostic Information
for Multiple Bus Systems.
No
Go to "Step 152h-29" on page 209.
Step 152h-33
Turn off the power.
Examine the green "power good out" LEDs of both I/O subsystem DCAs.
Step 152h-34
Are all the green "power good out" LEDs of both I/O subsystem DCAs off?
Yes
Go to "Step 152h-35".
No
Call for support.
Step 152h-35
Remove the following adapter cards, if present, from the I/O subsystem. Record the adapter locations:
v Adapter card at P2-I6
v Adapter card at P2-I7
v Adapter card at P2-I8
v Adapter card at P2-I9
v Adapter card at P2-I10
210
Eserver pSeries 670 Service Guide