IBM pSeries 670 Service Manual page 192

Hide thumbs Also See for pSeries 670:
Table of Contents

Advertisement

Step 152b-43
Turn on the power.
Step 152b-44
Did the system stop with the same error code as recorded in "Step 152b-1" on page 167?
Yes
Go to "Step 152b-45".
No
The system backplane was defective. This ends the procedure.
Return the system to its original configuration.
Go to "MAP 0410: Repair Checkout" in the RS/6000 and Eserver pSeries Diagnostic Information
for Multiple Bus Systems.
Step 152b-45
Turn off the power.
Make sure all amber logic-power LEDs of all installed processor subsystem DCAs are off.
Step 152b-46
Has the system backplane been replaced?
Yes
Call for support.
No
Go to "Step 152b-42" on page 171.
172
Eserver pSeries 670 Service Guide

Advertisement