Error Code Description
1024 1C06 Loss of airflow in third I/O subsystem in second
rack (I/O subsystem 7),
location: U2.13
1024 6014 Overcurrent or overvoltage problem with 3.3V in
third I/O subsystem in second rack (I/O
subsystem 7). Location:
U2.13
1024 6024 Overcurrent or overvoltage problem with 5.0V in
third I/O subsystem in second rack (I/O
subsystem 7). Location:
U2.13
1024 6034 Overcurrent or overvoltage problem with 2.5V in
third I/O subsystem in second rack (I/O
subsystem 7). Location:
U2.13
1024 6044 Overcurrent or overvoltage problem with 12.0V
in third I/O subsystem in second rack (I/O
subsystem 7). Location:
U2.13
1024 6054 Overcurrent or overvoltage problem with -12.0V
in third I/O subsystem in second rack (I/O
subsystem 7). Location:
U2.13
1024 6814 Overcurrent or overvoltage problem with 3.3V in
third I/O subsystem in second rack (I/O
subsystem 7). Location:
U2.13
1024 6824 Overcurrent or overvoltage problem with 5.0V in
third I/O subsystem in second rack (I/O
subsystem 7). Location:
U2.13
1024 6834 Overcurrent or overvoltage problem with 2.5V in
third I/O subsystem in second rack (I/O
subsystem 7). Location:
U2.13
1024 6844 Overcurrent or overvoltage problem with 12.0V
in third I/O subsystem in second rack (I/O
subsystem 7). Location:
U2.13
1024 6854 Overcurrent or overvoltage problem with -12.0V
in third I/O subsystem in second rack (I/O
subsystem 7). Location:
U2.13
1024 7017 Problem with fan 3 in third I/O subsystem in
second rack (I/O subsystem 7)
1024 7027 Problem with fan 4 in third I/O subsystem in
second rack (I/O subsystem 7)
404
Eserver pSeries 670 Service Guide
Action/
Possible Failing FRU
Go to "MAP 1527: An Airflow Loss Has Been
Detected" on page 160.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
1. DCA-1
Location: U2.13-V1
2. Fan 3
Location: U2.13-F3
1. DCA-2
Location: U2.13-V2
2. Fan 4
Location: U2.13-F4