Error Code Description
1016 xx61 Third I/O subsystem in primary rack, DASD
backplane 2 fault
1016 xx63 Seeprom fault on DASD backplane 2 in third I/O
subsystem in primary rack
1016 xx71 Third I/O subsystem in primary rack, DASD
backplane 3 fault
1016 xx73 Seeprom fault on DASD backplane 3 in third I/O
subsystem in primary rack
1016 xx81 Third I/O subsystem in primary rack, DASD
backplane 4 fault
1016 xx83 Seeprom fault on DASD backplane 4 in third I/O
subsystem in primary rack
1017 1B17 Problem with fan 1 in fourth I/O subsystem (no
IBF installed) in primary rack
1017 1B27 Problem with fan 2 in fourth I/O subsystem (no
IBF installed) in primary rack
1017 1C06 Loss of airflow in fourth I/O subsystem, no IBF
location: U1.13
1017 6014 Overcurrent or overvoltage problem with 3.3V in
fourth I/O subsystem, no IBF
1017 6024 Overcurrent or overvoltage problem with 5.0V in
fourth I/O subsystem, no IBF
1017 6034 Overcurrent or overvoltage problem with 2.5V in
fourth I/O subsystem, no IBF
1017 6044 Overcurrent or overvoltage problem with 12.0V
in fourth I/O subsystem, no IBF
1017 6054 Overcurrent or overvoltage problem with -12.0V
in fourth I/O subsystem, no IBF
1017 6814 Overcurrent or overvoltage problem with 3.3V in
fourth I/O subsystem, no IBF
1017 6824 Overcurrent or overvoltage problem with 5.0V in
fourth I/O subsystem, no IBF
1017 6834 Overcurrent or overvoltage problem with 2.5V in
fourth I/O subsystem, no IBF
1017 6844 Overcurrent or overvoltage problem with 12.0V
in fourth I/O subsystem, no IBF
1017 6854 Overcurrent or overvoltage problem with -12.0V
in fourth I/O subsystem, no IBF
1017 7017 Problem with fan 3 in fourth I/O subsystem (no
IBF installed) in primary rack
Action/
Possible Failing FRU
U1.1-P4
U1.1-P4
U1.1-P5
U1.1-P5
U1.1-P6
U1.1-P6
1. DCA-1
Location: U1.13-V1
2. Fan 1
Location: U1.13-F1
1. DCA-2
Location: U1.13-V2
2. Fan 2
Location: U1.13-F2
Go to "MAP 1527: An Airflow Loss Has Been
Detected" on page 160.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
1. DCA-1
Location: U1.13-V1
2. Fan 3
Location: U1.13-F3