Error Code Description
4065 0007 Display alter tests detected fault in L3 VPD
card
4065 000A Display alter tests detected fault in primary I/O
book 1 (slot 0)
4065 000B Display alter tests detected fault in secondary
I/O book (slot 1)
4065 000C Display alter tests detected fault in I/O book 3
(slot 2)
4065 000D Display alter tests detected fault in I/O book 4
(slot 3)
4065 000E CUoD capacity card
4065 0010 Display alter tests detected fault in Memory
book (slot 0)
4065 0011 Display alter tests detected fault in Memory
book (slot 1)
4065 0012 Display alter tests detected fault in Memory
book (slot 2)
4065 0013 Display alter tests detected fault in Memory
book (slot 3)
4065 0014 Display alter tests detected fault in Memory
book (slot 4)
4065 0015 Display alter tests detected fault in Memory
book (slot 5)
4065 0016 Display alter tests detected fault in Memory
book (slot 6)
4065 0017 Display alter tests detected fault in Memory
book (slot 7)
4065 00B0 Display alter tests detected possible problem
with bus controller or CSP code
4065 00B1 Display alter tests detected possible problem
with bus controller
Action/
Possible Failing FRU
1. L3 VPD card
Location: U1.18-P1-H2.1
(Order the L3 cache module FRU to obtain
a new L3 VPD card. Return the L3 cache
module that was included in the FRU kit,
and the failing L3 VPD card as "new
defective.")
2. Primary I/O book
Location: U1.18-P1-H2
Go to "MAP 1540: Problem Isolation
Procedures" on page 253.
Go to "MAP 1540: Problem Isolation
Procedures" on page 253.
Go to "MAP 1540: Problem Isolation
Procedures" on page 253.
Go to "MAP 1540: Problem Isolation
Procedures" on page 253.
1. Replace the CUoD capacity card
Location: U1.18-P1-H2.2
2. Ask the customer to reenter the CUoD
activation keys.
Memory book (slot 0)
Location: U1.18-P1-M2
Memory book (slot 1)
Location: U1.18-P1-M3
Memory book (slot 2)
Location: U1.18-P1-M7
Memory book (slot 3)
Location: U1.18-P1-M6
Memory book (slot 4)
Location: U1.18-P1-M4
Memory book (slot 5)
Location: U1.18-P1-M8
Memory book (slot 6)
Location: U1.18-P1-M5
Memory book (slot 7)
Location: U1.18-P1-M1
1. Check for system firmware updates.
2. Primary I/O book,
Location: U1.18-P1-H2
3. Call service support.
1. Check for system firmware updates.
2. Primary I/O book,
Location: U1.18-P1-H2
3. Call service support.
Chapter 5. Error Code to FRU Index
455