Symptom
You have a problem that does not prevent the system
from booting and the media subsystem operator panel is
functional.
You do not have a symptom.
You have an SRN.
The system stops and a 3-digit number is displayed in the
operator panel display.
The system stops and a 4-digit number beginning with 0
or 2 is displayed in the operator panel display.
All other symptoms.
112
Eserver pSeries 670 Service Guide
Starting Point
Go to the Fast Path MAP in the RS/6000 and Eserver
pSeries Diagnostic Information for Multiple Bus Systems.
Go to MAP 0020 in the RS/6000 and Eserver pSeries
Diagnostic Information for Multiple Bus Systems.
Go to the Fast Path MAP in the RS/6000 and Eserver
pSeries Diagnostic Information for Multiple Bus Systems.
Record SRN 101-xxx, where xxx is the 3-digit number
displayed in the operator panel display, then go to the
Fast Path MAP in the RS/6000 and Eserver pSeries
Diagnostic Information for Multiple Bus Systems.
Go to the Fast Path MAP in the RS/6000 and Eserver
pSeries Diagnostic Information for Multiple Bus Systems.
Go to "Quick Entry MAP" on page 113.