Error Code Description
1017 7027 Problem with fan 4 in fourth I/O subsystem (no
IBF installed) in primary rack
1017 7117 Problem with fan 1 and fan 3 in fourth I/O
subsystem (no IBF installed) in primary rack
1017 7127 Problem with fan 2 and fan 4 in fourth I/O
subsystem (no IBF installed) in primary rack
1017 B014 Overcurrent or overvoltage problem with 3.3V in
fourth I/O subsystem, no IBF
1017 B024 Overcurrent or overvoltage problem with 5.0V in
fourth I/O subsystem, no IBF
1017 B034 Overcurrent or overvoltage problem with 2.5V in
fourth I/O subsystem, no IBF
1017 B044 Overcurrent or overvoltage problem with 12.0V
in fourth I/O subsystem, no IBF
1017 B054 Overcurrent or overvoltage problem with -12.0V
in fourth I/O subsystem, no IBF
1017 B814 Overcurrent or overvoltage problem with 3.3V in
fourth I/O subsystem, no IBF
1017 B824 Overcurrent or overvoltage problem with 5.0V in
fourth I/O subsystem, no IBF
1017 B834 Overcurrent or overvoltage problem with 2.5V in
fourth I/O subsystem, no IBF
1017 B844 Overcurrent or overvoltage problem with 12.0V
in fourth I/O subsystem, no IBF
1017 B854 Overcurrent or overvoltage problem with -12.0V
in fourth I/O subsystem, no IBF
1017 BF06 Unable to resolve the chassis VPD in an I/O
subsystem
1017 CD96 A power short has been detected in the DASD
subsystem in an I/O drawer.
1017 CDA6 A power short has been detected in the DASD
subsystem in an I/O drawer.
1017 CDB6 A power short has been detected in the DASD
subsystem in an I/O drawer.
368
Eserver pSeries 670 Service Guide
Action/
Possible Failing FRU
1. DCA-2
Location: U1.13-V2
2. Fan 4
Location: U1.13-F4
1. DCA-1
Location: U1.13-V1
2. Fans 1 and 3
Location: U1.13-F1 and U1.13-F3
1. DCA-2
Location: U1.13-V2
2. Fans 2 and 4
Location: U1.13-F2 and U1.13-F4
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
The chassis VPD in the I/O subsystem drawer
identified by the location code could not be
resolved. This may be an indication that more
than one FRU in the drawer was replaced during
a service action. If this is the case, reinstall the
original FRUs in the drawer, then replace the
FRUs one at a time.
If only one FRU was replaced and this error
code occurred, call service support.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.