Error Code Description
450F 28B0 Memory subsystem and error code
generation/logging detected fault in I/O
subsystem PCI backplane
450F 28B1 Memory subsystem and error code
generation/logging detected fault in I/O
subsystem DASD backplane
450F 302A Memory subsystem and error code
generation/logging detected fault in 8 GB
memory book (inner)
450F 302B Memory subsystem and error code
generation/logging detected fault in 8 GB
memory book (outer)
450F 302C Memory subsystem and error code
generation/logging detected fault in 32 GB
memory book (inner)
450F 302D Memory subsystem and error code
generation/logging detected fault in 32 GB
memory book (outer)
450F 305A Memory subsystem and processor subsystem
tests detected fault in 8 GB memory book
(inner)
450F 305B Memory subsystem and processor subsystem
tests detected fault in 8 GB memory book
(outer)
450F 305C Memory subsystem and error code
generation/logging detected fault in 4 GB inner
memory book
450F 305D Memory subsystem and error code
generation/logging detected fault in 4 GB outer
memory book
450F 305E Memory subsystem and error code
generation/logging detected fault in 16 GB inner
memory book
450F 305F Memory subsystem and error code
generation/logging detected fault in 16 GB outer
memory book
450F 307A Memory subsystem and processor subsystem
tests detected fault in 4 GB inner memory book
450F 307B Memory subsystem and processor subsystem
tests detected fault in 8 GB inner memory book
450F 307C Memory subsystem and processor subsystem
tests detected fault in 16 GB inner memory
book
450F 307D Memory subsystem and processor subsystem
tests detected fault in 16 GB inner memory
book
450F 307E Memory subsystem and processor subsystem
tests detected fault in 16 GB inner memory
book
Action/
Possible Failing FRU
I/O subsystem PCI backplane at location
specified in error code
I/O subsystem DASD backplane at location
specified in error code
Go to "MAP 1540: Problem Isolation
Procedures" on page 253 to isolate the failing
component.
Go to "MAP 1540: Problem Isolation
Procedures" on page 253 to isolate the failing
component.
Go to "MAP 1540: Problem Isolation
Procedures" on page 253 to isolate the failing
component.
Go to "MAP 1540: Problem Isolation
Procedures" on page 253 to isolate the failing
component.
Go to "MAP 1544: Inner L3 Module Problem
Isolation" on page 282.
Go to "MAP 1545: Outer L3 Module Problem
Isolation" on page 284.
Go to "MAP 1544: Inner L3 Module Problem
Isolation" on page 282.
Go to "MAP 1545: Outer L3 Module Problem
Isolation" on page 284.
Go to "MAP 1544: Inner L3 Module Problem
Isolation" on page 282.
Go to "MAP 1545: Outer L3 Module Problem
Isolation" on page 284.
Go to "MAP 1544: Inner L3 Module Problem
Isolation" on page 282.
Go to "MAP 1544: Inner L3 Module Problem
Isolation" on page 282.
Go to "MAP 1544: Inner L3 Module Problem
Isolation" on page 282.
Go to "MAP 1544: Inner L3 Module Problem
Isolation" on page 282.
Go to "MAP 1544: Inner L3 Module Problem
Isolation" on page 282.
Chapter 5. Error Code to FRU Index