Error Code Description
1011 8424 No MCM 2 VPD card or MCM
1011 8425 No MCM 1 VPD card or MCM
1011 8426 No MCM 3 VPD card or MCM
1011 8430 SPCN configuration mismatch
1011 8431 SPCN configuration mismatch
1011 8440 SPCN configuration mismatch
1011 8441 SPCN configuration mismatch
1011 8468 Capacitor card fault
Action/
Possible Failing FRU
1. Location: U1.18-P1-H2.4 and U1.18-P1-C4
See note on page 441.
2. Primary I/O book
Location: U1.18-P1-H2
1. Location: U1.18-P1-H2.5 and U1.18-P1-C3
See note on page 441.
2. Primary I/O book
Location: U1.18-P1-H2
1. Location: U1.18-P1-H2.6 and U1.18-P1-C2
See note on page 441.
2. Primary I/O book
Location: U1.18-P1-H2
1. Set I/O type to correct value. See "Change
I/O Type" on page 728.
2. Primary I/O book
Location: U1.18-P1-H2
1. Set I/O type to correct value. See "Change
I/O Type" on page 728.
2. Primary I/O book
Location: U1.18-P1-H2
1. Set I/O type to correct value. See "Change
I/O Type" on page 728.
2. Primary I/O book
Location: U1.18-P1-H2
1. Set I/O type to correct value. See "Change
I/O Type" on page 728.
2. Primary I/O book
Location: U1.18-P1-H2
1. If fewer than 3 DCAs are installed:
a. If no capacitor card is installed in
U1.18-P1-V3 or U1.18-P1-V7, install a
card in U1.18-P1-V3.
b. If a capacitor card is present in either
U1.18-P1-V3 or U1.18-P1-V7, reseat it. If
the problem is not fixed, replace it.
2. If 3 or more DCAs are installed:
a. If no capacitor card is installed in
U1.18-P1-V3, one is required.
b. If a capacitor card is installed in
U1.18-P1-V3, reseat it. If the problem is
not fixed, replace it.
3. If the same error code reoccurs, replace the
primary I/O book, location: U1.18-P1-H2.