IBM pSeries 670 Service Manual page 471

Hide thumbs Also See for pSeries 670:
Table of Contents

Advertisement

Error Code Description
4064 0BF8 Processor subsystem tests detected fault in I/O
hub chip 8 (port x)
4064 0BF9 Processor subsystem tests detected fault in I/O
hub chip 9 (port x)
4064 0BFA Processor subsystem tests detected fault in I/O
hub chip 10 (port x)
4064 0BFB Processor subsystem tests detected fault in I/O
hub chip 11 (port x)
4064 0BFC Processor subsystem tests detected fault in I/O
hub chip 12 (port x)
4064 0BFD Processor subsystem tests detected fault in I/O
hub chip 13 (port x)
4064 0C03 Processor subsystem tests detected fault in all
MCMs
4064 0C09 Processor subsystem tests detected fault in all
memory books
4064 0C0A Processor subsystem tests detected fault in all
I/O books
4064 0C10 Processor subsystem tests detected mismatch
between MCM 0 and VPD card
4064 0C11 Processor subsystem tests detected mismatch
between MCM 2 and VPD card
Action/
Possible Failing FRU
1. Check the cabling on the following RIO
ports:
a. U1.18-P1-H1/Q7
b. U1.18-P1-H1/Q8
2. Replace the RIO book,
Location: U1.18-P1-H1
1. Check the cabling on the following RIO
ports:
a. U1.18-P1-H1/Q5
b. U1.18-P1-H1/Q6
2. Replace the RIO book,
Location: U1.18-P1-H1
1. Check the cabling on the following RIO
ports:
a. U1.18-P1-H3/Q3
b. U1.18-P1-H3/Q4
2. Replace the RIO book,
Location: U1.18-P1-H3
1. Check the cabling on the following RIO
ports:
a. U1.18-P1-H3/Q1
b. U1.18-P1-H3/Q2
2. Replace the RIO book,
Location: U1.18-P1-H3
1. Check the cabling on the following RIO
ports:
a. U1.18-P1-H4/Q1
b. U1.18-P1-H4/Q2
2. Replace the RIO book,
Location: U1.18-P1-H4.
1. Check the cabling on the following RIO
ports:
a. U1.18-P1-H4/Q3
b. U1.18-P1-H4/Q4
2. Replace the RIO book,
Location: U1.18-P1-H4
Go to "MAP 1543: MCM Module Problem
Isolation" on page 280.
Go to "MAP 1546: Memory Book Problem
Isolation" on page 286.
Go to "MAP 1547: I/O Book Problem Isolation"
on page 288.
Plugging error with FRU kit
Location: U1.18-P1-C1 and U1.18-P1-H2.3
Plugging error with FRU kit
Location: U1.18-P1-C4 and U1.18-P1-H2.4
Chapter 5. Error Code to FRU Index
451

Advertisement

Table of Contents
loading

Table of Contents