Error Code Description
1015 B814 Overcurrent or overvoltage problem with 3.3V in
second I/O subsystem
1015 B824 Overcurrent or overvoltage problem with 5.0V in
second I/O subsystem
1015 B834 Overcurrent or overvoltage problem with 2.5V in
second I/O subsystem
1015 B844 Overcurrent or overvoltage problem with 12.0V
in second I/O subsystem
1015 B854 Overcurrent or overvoltage problem with -12.0V
in second I/O subsystem
1015 BF06 Unable to resolve the chassis VPD in an I/O
subsystem
1015 CD96 A power short has been detected in the DASD
subsystem in an I/O drawer.
1015 CDA6 A power short has been detected in the DASD
subsystem in an I/O drawer.
1015 CDB6 A power short has been detected in the DASD
subsystem in an I/O drawer.
1015 CDC6 A power short has been detected in the DASD
subsystem in an I/O drawer.
1015 F4x6 Hardware configuration does not support
N-mode power.
1015 F516 An N+1 boundary (DCA or fan) has dropped to
N-mode status in the second I/O subsystem,
location: U1.5.
1015 F526 An N+1 boundary (DCA or fan) has dropped to
N-mode status in the second I/O subsystem,
location: U1.5.
1015 xx11 Second I/O subsystem in primary rack, DCA-1
1015 xx13 Seeprom fault on DCA-1 in second I/O
subsystem in primary rack
362
Eserver pSeries 670 Service Guide
Action/
Possible Failing FRU
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
The chassis VPD in the I/O subsystem drawer
identified by the location code could not be
resolved. This may be an indication that more
than one FRU in the drawer was replaced during
a service action. If this is the case, reinstall the
original FRUs in the drawer, then replace the
FRUs one at a time.
If only one FRU was replaced and this error
code occurred, call service support.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Call Service Support
This is normally an informational message. It
should be accompanied by other error codes
that more precisely indicate where the failure is.
Examine the service processor error log. If there
are no other power-related error codes (in the
time frame in which this code was generated) in
the service processor error log, the FRU
indicated with this error code, if any, should be
replaced.
This is normally an informational message. It
should be accompanied by other error codes
that more precisely indicate where the failure is.
Examine the service processor error log. If there
are no other power-related error codes (in the
time frame in which this code was generated) in
the service processor error log, the FRU
indicated with this error code, if any, should be
replaced.
U1.5-V1
U1.5-V1