IBM pSeries 670 Service Manual page 408

Hide thumbs Also See for pSeries 670:
Table of Contents

Advertisement

Error Code Description
101C B124 Overcurrent or overvoltage problem with 1.5V in
processor subsystem
101C B134 Overcurrent or overvoltage problem with 1.5V in
processor subsystem
101C B144 Overcurrent or overvoltage problem with 3.3V in
processor subsystem (oscillator)
101C B544 Overcurrent or overvoltage problem with 5.0V in
processor subsystem (autostart, standby)
101C B814 Overcurrent or overvoltage problem with 2.5V in
processor subsystem
101C B914 Overcurrent or overvoltage problem with 1.8V in
processor subsystem
101C B924 Overcurrent or overvoltage problem with 1.5V in
processor subsystem
101C B934 Overcurrent or overvoltage problem with 1.5V in
processor subsystem
101C B944 Overcurrent or overvoltage problem with 3.3V in
processor subsystem (oscillator)
101C BD44 Overcurrent or overvoltage problem with 5.0V in
processor subsystem (autostart, standby)
101C E006 Processor over-temperature detected
101C E106 Processor over-temperature detected
101C E1B6 MCM 0 running over temperature
101C E1C6 MCM 1 running over temperature
388
Eserver pSeries 670 Service Guide
Action/
Possible Failing FRU
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1528: There Is A Processor
(Critical/Warning) Overtemperature Fault" on
page 162.
Go to "MAP 1528: There Is A Processor
(Critical/Warning) Overtemperature Fault" on
page 162.
1. Verify that the MCM at U1.18-P1-C1 is
installed.
2. Verify that there are no airflow problems with
the MCM at U1.18-P1-C1 or its heatsink.
3. Verify that the MCM at U1.18-P1-C1 is
installed correctly onto the processor
backplane.
4. Call service support.
1. Verify that the MCM at U1.18-P1-C3 is
installed.
2. Verify that there are no airflow problems with
the MCM at U1.18-P1-C3 or its heatsink.
3. Verify that the MCM at U1.18-P1-C3 is
installed correctly onto the processor
backplane.
4. Call service support.

Advertisement

Table of Contents
loading

Table of Contents