Error Code Description
406D 0C12 Attention handler detected mismatch between
MCM 1 and VPD card
406D 0C13 Attention handler detected mismatch between
MCM 3 and VPD card
406D 0CA5 Attention handler detected invalid processor
subsystem configuration
406D 0CA6 Attention handler detected no usable main
storage
406D 0CA9 Attention handler detected configuration error
with processor memory
406D 0D00 Attention handler detected fault in L3 cache
module 0
406D 0D01 Attention handler detected fault in L3 cache
module 1
406D 0D02 Attention handler detected fault in L3 cache
module 2
406D 0D03 Attention handler detected fault in L3 cache
module 3
406D 0D04 Attention handler detected fault in L3 cache
module 4
406D 0D05 Attention handler detected fault in L3 cache
module 5
406D 0D06 Attention handler detected fault in L3 cache
module 6
406D 0D07 Attention handler detected fault in L3 cache
module 7
406D 0D08 Attention handler detected fault in L3 cache
module 8
406D 0D09 Attention handler detected fault in L3 cache
module 9
406D 0D0A Attention handler detected fault in L3 cache
module 10
406D 0D0B Attention handler detected fault in L3 cache
module 11
406D 0D0C Attention handler detected fault in L3 cache
module 12
406D 0D0D Attention handler detected fault in L3 cache
module 13
406D 0D0E Attention handler detected fault in L3 cache
module 14
406D 0D0F Attention handler detected fault in L3 cache
module 15
578
Eserver pSeries 670 Service Guide
Action/
Possible Failing FRU
Plugging error with FRU kit
Location: U1.18-P1-C3 and U1.18-P1-H2.5
Plugging error with FRU kit
Location: U1.18-P1-C2 and U1.18-P1-H2.6
Verify that MCMs, memory books, and L3
modules are correctly configured.
Reboot the system in slow mode to isolate the
failure.
Reboot the system in slow mode to isolate the
failure.
L3 cache module 0 and L3 VPD card
Location: U1.18-P1-C6 and U1.18-P1-H2.1
L3 cache module 1 and L3 VPD card
Location: U1.18-P1-C7 and U1.18-P1-H2.1
L3 cache module 2 and L3 VPD card
Location: U1.18-P1-C11 and U1.18-P1-H2.1
L3 cache module 3 and L3 VPD card
Location: U1.18-P1-C10 and U1.18-P1-H2.1
L3 cache module 4 and L3 VPD card
Location: U1.18-P1-C8 and U1.18-P1-H2.1
L3 cache module 5 and L3 VPD card
Location: U1.18-P1-C20 and U1.18-P1-H2.1
L3 cache module 6 and L3 VPD card
Location: U1.18-P1-C16 and U1.18-P1-H2.1
L3 cache module 7 and L3 VPD card
Location: U1.18-P1-C12 and U1.18-P1-H2.1
L3 cache module 8 and L3 VPD card
Location: U1.18-P1-C19 and U1.18-P1-H2.1
L3 cache module 9 and L3 VPD card
Location: U1.18-P1-C18 and U1.18-P1-H2.1
L3 cache module 10 and L3 VPD card
Location: U1.18-P1-C14 and U1.18-P1-H2.1
L3 cache module 11 and L3 VPD card
Location: U1.18-P1-C15 and U1.18-P1-H2.1
L3 cache module 12 and L3 VPD card
Location: U1.18-P1-C17 and U1.18-P1-H2.1
L3 cache module 13 and L3 VPD card
Location: U1.18-P1-C5 and U1.18-P1-H2.1
L3 cache module 14 and L3 VPD card
Location: U1.18-P1-C9 and U1.18-P1-H2.1
L3 cache module 15 and L3 VPD card
Location: U1.18-P1-C13 and U1.18-P1-H2.1