Error Code Description
1021 7027 Problem with fan 4 in first I/O subsystem in
second rack (I/O subsystem 5)
1021 7117 Problem with fan 1 and fan 3 in first I/O
subsystem in second rack (I/O subsystem 5)
1021 7127 Problem with fan 2 and fan 4 in first I/O
subsystem in second rack (I/O subsystem 5)
1021 B014 Overcurrent or overvoltage problem with 3.3V in
5th I/O subsystem
1021 B024 Overcurrent or overvoltage problem with 5.0V in
5th I/O subsystem
1021 B034 Overcurrent or overvoltage problem with 2.5V in
5th I/O subsystem
1021 B044 Overcurrent or overvoltage problem with 12.0V
in 5th I/O subsystem
1021 B054 Overcurrent or overvoltage problem with -12.0V
in 5th I/O subsystem
1021 B814 Overcurrent or overvoltage problem with 3.3V in
5th I/O subsystem
1021 B824 Overcurrent or overvoltage problem with 5.0V in
5th I/O subsystem
1021 B834 Overcurrent or overvoltage problem with 2.5V in
5th I/O subsystem
1021 B844 Overcurrent or overvoltage problem with 12.0V
in 5th I/O subsystem
1021 B854 Overcurrent or overvoltage problem with -12.0V
in 5th I/O subsystem
1021 BF06 Unable to resolve the chassis VPD in an I/O
subsystem
1021 CD96 A power short has been detected in the DASD
subsystem in an I/O drawer.
1021 CDA6 A power short has been detected in the DASD
subsystem in an I/O drawer.
1021 CDB6 A power short has been detected in the DASD
subsystem in an I/O drawer.
394
Eserver pSeries 670 Service Guide
Action/
Possible Failing FRU
1. DCA-2
Location: U2.1-V2
2. Fan 4
Location: U2.1-F4
1. DCA-1
Location: U2.1-V1
2. Fans 1 and 3
Location: U2.1-F1 and U2.1-F3
1. DCA-2
Location: U2.1-V2
2. Fans 2 and 4
Location: U2.1-F2 and U2.1-F4
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
The chassis VPD in the I/O subsystem drawer
identified by the location code could not be
resolved. This may be an indication that more
than one FRU in the drawer was replaced during
a service action. If this is the case, reinstall the
original FRUs in the drawer, then replace the
FRUs one at a time.
If only one FRU was replaced and this error
code occurred, call service support.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.