IBM pSeries 670 Service Manual page 488

Hide thumbs Also See for pSeries 670:
Table of Contents

Advertisement

Error Code Description
4065 0EB9 Attention line 8 stuck fault
4065 0EBA Attention line 9 stuck fault
4065 0EBB Attention line 10 stuck fault
4065 0EBC Attention line 11 stuck fault
4065 0EBF Memory error
4065 0EE1 Display alter tests detected fault in service
processor code (invalid MRU to mapping)
4065 0EE2 Display alter tests detected fault in service
processor firmware fault
4065 0EE5 Display alter tests detected firmware error; no
callout available
4065 25E6 SMA 4-port switch adapter fault
4065 273F SMA 2-port switch adapter fault
4066 0001 Scan interface basic assurance tests detected
clock card assembly failure
4066 0002 Scan interface basic assurance tests detected
backplane assembly failure
4066 0003 Scan interface basic assurance tests detected
fault in MCM module 0
4066 0004 Scan interface basic assurance tests detected
fault in MCM module 2
4066 0005 Scan interface basic assurance tests detected
fault in MCM module 1
4066 0006 Scan interface basic assurance tests detected
fault in MCM module 3
468
Eserver pSeries 670 Service Guide
Action/
Possible Failing FRU
Go to "MAP 1540: Problem Isolation
Procedures" on page 253.
Go to "MAP 1540: Problem Isolation
Procedures" on page 253.
Go to "MAP 1540: Problem Isolation
Procedures" on page 253.
Go to "MAP 1540: Problem Isolation
Procedures" on page 253.
1. Reboot the system in slow mode to the
SMS menus. See "Performing Slow Boot"
on page 345.
2. Examine the service processor error log.
v If a CEC subsystem error (a 4xxx yyyy
error) occurred during the slow boot that
calls out the memory, processors, L3
cache modules, or the primary I/O book,
replace the part indicated by the location
code.
v If a CEC subsystem error (a 4xxx yyyy
error) did not occur during the slow boot,
look for a 4xxx yyyy error immediately
preceding the 406x 0EBF error. Replace
the part indicated by the location code
associated with that error.
1. Check for system firmware updates.
2. Call service support.
1. Check for system firmware updates.
2. Call service support.
1. Check for system firmware updates.
2. Call service support.
Replace the I/O book (switch adapter) specified
by the location code.
Replace the I/O book (switch adapter) specified
by the location code.
Go to "MAP 1540: Problem Isolation
Procedures" on page 253.
Go to "MAP 1540: Problem Isolation
Procedures" on page 253.
MCM module 0 and VPD card
Location: U1.18-P1-C1 and U1.18-P1-H2.3
MCM module 2 and VPD card
Location: U1.18-P1-C4 and U1.18-P1-H2.4
MCM module 1 and VPD card
Location: U1.18-P1-C3 and U1.18-P1-H2.5
MCM module 3 and VPD card
Location: U1.18-P1-C2 and U1.18-P1-H2.6

Advertisement

Table of Contents
loading