Error Code Description
1023 BF06 Unable to resolve the chassis VPD in an I/O
subsystem
1023 CD96 A power short has been detected in the DASD
subsystem in an I/O drawer.
1023 CDA6 A power short has been detected in the DASD
subsystem in an I/O drawer.
1023 CDB6 A power short has been detected in the DASD
subsystem in an I/O drawer.
1023 CDC6 A power short has been detected in the DASD
subsystem in an I/O drawer.
1023 F4x6 Hardware configuration does not support
N-mode power.
1023 F516 An N+1 boundary (DCA or fan) has dropped to
N-mode status in the fourth subsystem (with IBF,
location: U2.9.
1023 F526 An N+1 boundary (DCA or fan) has dropped to
N-mode status in the fourth I/O subsystem (with
IBF), location: U2.9.
1023 xx11 Fourth I/O subsystem moves to second rack
(with IBF), DCA-1
1023 xx13 Seeprom fault on DCA-1 in fourth I/O subsystem
(with IBF) in secondary rack
1023 xx15 Fourth I/O subsystem moves to second rack
(with IBF), DCA-1, cable fault
1023 xx17 Problem with fan 1 and fan 3 in fourth I/O
subsystem (with IBF, moves to second rack)
402
Eserver pSeries 670 Service Guide
Action/
Possible Failing FRU
The chassis VPD in the I/O subsystem drawer
identified by the location code could not be
resolved. This may be an indication that more
than one FRU in the drawer was replaced during
a service action. If this is the case, reinstall the
original FRUs in the drawer, then replace the
FRUs one at a time.
If only one FRU was replaced and this error
code occurred, call service support.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Call Service Support
This is normally an informational message. It
should be accompanied by other error codes
that more precisely indicate where the failure is.
Examine the service processor error log. If there
are no other power-related error codes (in the
time frame in which this code was generated) in
the service processor error log, the FRU
indicated with this error code, if any, should be
replaced.
This is normally an informational message. It
should be accompanied by other error codes
that more precisely indicate where the failure is.
Examine the service processor error log. If there
are no other power-related error codes (in the
time frame in which this code was generated) in
the service processor error log, the FRU
indicated with this error code, if any, should be
replaced.
U2.9-V1
U2.9-V1
Go to "MAP 1520: Power" on page 144 with
these pairs of location codes:
1. U2.9-V1/Q1 and U1.35-P2-X2/Q5
2. U2.9-V1/Q2 and U1.35-P1-X2/Q5
1. DCA-1
Location U2.9–V1
2. Fan 1,
Location U2.9–F1
3. Fan 3,
Location U2.9–F3