Step 152l-11
Did the system stop with the same error code as recorded in "Step 152l-1" on page 239?
Yes
The card just reinserted is defective. Replace it. This ends the procedure.
Return the system to its original configuration.
Go to "MAP 0410: Repair Checkout" in the RS/6000 and Eserver pSeries Diagnostic Information
for Multiple Bus Systems.
No
Go to "Step 152l-12".
Step 152l-12
Have all the cards listed in "Step 152l-5" on page 239 been reinserted?
Yes
The symptom has changed. This ends the procedure.
Return the system to its original configuration.
Go to "MAP 0410: Repair Checkout" in the RS/6000 and Eserver pSeries Diagnostic Information
for Multiple Bus Systems.
No
Go to "Step 152l-9" on page 239.
Step 152l-13
Turn off the power.
Examine the green "power good out" LEDs of both I/O subsystem DCAs.
Step 152l-14
Are all the green "power good out" LEDs of both I/O subsystem DCAs off?
Yes
Go to "Step 152l-15".
No
Call for support.
Step 152l-15
Remove the following adapter cards, if present, from the I/O subsystem. Record the adapter locations:
v Adapter card at P1-I6
v Adapter card at P1-I7
v Adapter card at P1-I8
v Adapter card at P1-I9
v Adapter card at P1-I10
Step 152l-16
Turn on the power.
Step 152l-17
Did the system stop with the same error code as recorded in "Step 152l-1" on page 239?
Yes
Go to "Step 152l-23" on page 241.
No
Go to "Step 152l-18".
Step 152l-18
One of the cards just removed is defective.
Turn off the power.
Make sure all the green "power good out" LEDs of both I/O subsystem DCAs are off.
240
Eserver pSeries 670 Service Guide