5. Use a 5-mm nut driver to loosen the set screw in the center of the L3 module spring plates as shown
in the following illustration..
6. Slide both plates up and pull them away from the L3 cache module.
7. Remove the sleeves from the posts.
8. Use a disposable lint-free cloth to clean the sleeves.
9. Pull the L3 cache module straight back off the posts, and place it with the interposer, facing down in
the four-position tray from the tool kit.
10. Clean the LGA site using the brush supplied with the new module.
Note: Before you remove the brush from its protective bag, loosen the bristles by pressing them on
the ESD mat until they are 90 degrees from the handle.
820
Eserver pSeries 670 Service Guide
1 Protective Cover
2 L3 Cache Module and Heatsink
3 Load Posts
1
2
3
4
5
6
4 Rear Spring Plate
5 Front Spring Plate with Set
Screw
6 L3 Filler (Used if no L3 cache
module is installed)