Error Code Description
4607 2806 I/O subsystem and processor subsystem tests
detected fault in I/O book 1, 3, or 4
4607 28B0 I/O subsystem and bus tests detected fault in
I/O subsystem PCI backplane
4607 28B1 I/O subsystem and bus tests detected fault in
I/O subsystem DASD backplane
4607 525E CUoD capacity card fault
4607 525F CUoD capacity card fault
4607 527A CUoD capacity card fault
4607 527C CUoD capacity card fault
4608 248B I/O subsystem and other bus tests detected
fault in operator panel
4608 25C0 I/O subsystem and other bus tests detected
fault in system backplane
4608 25C1 I/O subsystem and other bus tests detected
fault in 1.0 GHz clock card
4608 2738 I/O subsystem and other bus tests detected
fault in I/O book 1, 3, or 4
Action/
Possible Failing FRU
1. If word 13 is CFF1 xxxx, a configuration
problem exists. Ensure that the number of
MCMs is consistent with the number of I/O
books.
2. Replace I/O book 1, 3, or 4 at location
specified in error code.
I/O subsystem PCI backplane at location
specified in error code
I/O subsystem DASD backplane at location
specified in error code
1. Verify that the system firmware is RH021114
or later. CUoD is not supported by the
earlier firmware levels.
2. Replace the CUoD capacity card,
location: U1.18-P1-H2.2, then ask the
customer to reenter the CUoD activation
keys.
1. Verify that the system firmware is RH021114
or later. CUoD is not supported by the
earlier firmware levels.
2. Replace the CUoD capacity card,
location: U1.18-P1-H2.2, then ask the
customer to reenter the CUoD activation
keys.
1. Verify that the system firmware is RH021114
or later. CUoD is not supported by the
earlier firmware levels.
2. Replace the CUoD capacity card,
location: U1.18-P1-H2.2, then ask the
customer to reenter the CUoD activation
keys.
1. Verify that the system firmware is RH021114
or later. CUoD is not supported by the
earlier firmware levels.
2. Replace the CUoD capacity card,
location: U1.18-P1-H2.2, then ask the
customer to reenter the CUoD activation
keys.
Operator panel
Location: U1.17-L1
System backplane
Location: U1.18-P1
Clock card
Location: U1.18-P1-X5
1. If word 13 is CFF1 xxxx, a configuration
problem exists. Ensure that the number of
MCMs is consistent with the number of I/O
books.
2. Replace I/O book 1, 3, or 4 at location
specified in error code.
Chapter 5. Error Code to FRU Index
649