IBM pSeries 670 Service Manual page 267

Hide thumbs Also See for pSeries 670:
Table of Contents

Advertisement

Step 152m-7
Is the power-on LED of the first FRU generated from the location codes recorded in "Step 152m-1"
on page 246 off?
Yes
Go to "Step 152m-8".
No
Call for support.
Step 152m-8
Replace the first FRU in the list of FRUs recorded in "Step 152m-1" on page 246 with power-on LED off.
Press the white service complete button on the panel with the UEPO switch after replacement.
Step 152m-9
Does the error code recorded in "Step 152m-1" on page 246 reappear?
Yes
Return the system to its original configuration. Go to "Step 152m-11".
Return the system to its original configuration. Go to "MAP 0410: Repair Checkout" in the
No
RS/6000 and Eserver pSeries Diagnostic Information for Multiple Bus Systems.
Step 152m-10
Press the white service complete button on the panel with the UEPO switch.
Step 152m-11
Schedule non-concurrent service with the customer to replace the second FRU in the list of FRUs
recorded in "Step 152m-1" on page 246. This ends the procedure.
Step 152m-12
Is the power-on LED of the first FRU generated from the location codes recorded in "Step 152m-1"
on page 246 off?
Yes
Go to "Step 152m-13".
No
Call for support.
Step 152m-13
Reseat and properly connect the power cable ends, with location codes recorded in "Step 152m-1" on
page 246.
Step 152m-14
Set the power-on switches of all BPRs on the same side with the power cable that was not connected
properly to the off (right) position.
Step 152m-15
Wait 30 seconds and then turn the power-on switches of the BPRs found in "Step 152m-14" to the on (left)
position.
Step 152m-16
Press the white service complete button on the panel with the UEPO switch after replacement.
Step 152m-17
Does the error code recorded in "Step 152m-1" on page 246 reappear?
Yes
Go to "Step 152m-2" on page 246.
Return the system to its original configuration. Go to "MAP 0410: Repair Checkout" in the
No
RS/6000 and Eserver pSeries Diagnostic Information for Multiple Bus Systems.
Chapter 3. Maintenance Analysis Procedures
247

Advertisement

Table of Contents
loading

Table of Contents