Error Code Description
460F 2776 I/O subsystem and processor subsystem tests
detected fault in I/O book 1, 3, or 4
460F 2806 I/O subsystem and processor subsystem tests
detected fault in I/O book 1, 3, or 4
460F 28B0 I/O subsystem and error code
generation/logging detected fault in I/O
subsystem PCI backplane
460F 28B1 I/O subsystem and error code
generation/logging detected fault in I/O
subsystem DASD backplane
460F 525E CUoD capacity card fault
460F 525F CUoD capacity card fault
460F 527A CUoD capacity card fault
460F 527C CUoD capacity card fault
Action/
Possible Failing FRU
1. If word 13 is CFF1 xxxx, a configuration
problem exists. Ensure that the number of
MCMs is consistent with the number of I/O
books.
2. Replace I/O book 1, 3, or 4 at location
specified in error code.
1. If word 13 is CFF1 xxxx, a configuration
problem exists. Ensure that the number of
MCMs is consistent with the number of I/O
books.
2. Replace I/O book 1, 3, or 4 at location
specified in error code.
I/O subsystem PCI backplane at location
specified in error code
I/O subsystem DASD backplane at location
specified in error code
1. Verify that the system firmware is RH021114
or later. CUoD is not supported by the
earlier firmware levels.
2. Replace the CUoD capacity card,
location: U1.18-P1-H2.2, then ask the
customer to reenter the CUoD activation
keys.
1. Verify that the system firmware is RH021114
or later. CUoD is not supported by the
earlier firmware levels.
2. Replace the CUoD capacity card,
location: U1.18-P1-H2.2, then ask the
customer to reenter the CUoD activation
keys.
1. Verify that the system firmware is RH021114
or later. CUoD is not supported by the
earlier firmware levels.
2. Replace the CUoD capacity card,
location: U1.18-P1-H2.2, then ask the
customer to reenter the CUoD activation
keys.
1. Verify that the system firmware is RH021114
or later. CUoD is not supported by the
earlier firmware levels.
2. Replace the CUoD capacity card,
location: U1.18-P1-H2.2, then ask the
customer to reenter the CUoD activation
keys.
Chapter 5. Error Code to FRU Index
659