Error Code Description
21F0 0004 SCSI CD-ROM: send diagnostic failed - devofl
command
21F2 0001 SCSI read/write optical device: test unit ready
failed; hardware error
21F2 0002 SCSI read/write optical device: test unit ready
failed; sense data available
21F2 0003 SCSI read/write optical drive: send diagnostic
failed; sense data available
21F2 0004 SCSI read/write optical drive: send diagnostic
failed - devofl command
2200 0001 PCI Ethernet BNC/RJ-45 or PCI Ethernet
AUI/RJ-45 Adapter
Internal Wrap Test failure
2200 1001 10/100 Mbps Ethernet PCI Adapter
Internal Wrap Test failure
2200 1002 10/100 Mbps Ethernet PCI Adapter failure
2201 0001 PCI Auto LANstreamer Token Ring Adapter
Adapter failed to complete hardware
initialization.
2201 1001 PCI Token Ring Adapter
Adapter failed to complete hardware
initialization.
20EE 0013 Unable to allocate memory for root-lpar-vpd
vpd
430
Eserver pSeries 670 Service Guide
Action/
Possible Failing FRU
Before replacing any system components,
refer to the Action under error code 21A0
0001.
Replace the SCSI device.
Before replacing any system components,
refer to the Action under error code 21A0
0001.
1. Replace the SCSI device.
2. Replace the SCSI cable.
3. Replace the SCSI controller.
Before replacing any system components,
refer to the Action under error code 21A0
0001.
1. Replace the SCSI device.
2. Replace the media.
Before replacing any system components,
refer to the Action under error code 21A0
0001.
Replace the SCSI drive.
Before replacing any system components,
refer to the Action under error code 21A0
0001.
Replace the SCSI drive.
Replace the Adapter.
See "Determining Location Code" on
page 347 for location code information related
to this error.
Replace the adapter.
See "Determining Location Code" on
page 347 for location code information related
to this error.
Replace the adapter.
See "Determining Location Code" on
page 347 for location code information related
to this error.
Replace the adapter.
See "Determining Location Code" on
page 347 for location code information related
to this error.
Replace the adapter.
See "Determining Location Code" on
page 347 for location code information related
to this error.
1. Verify that the system is in LPAR mode,
and reboot the system.
2. Reflash the system with the latest level of
system firmware.
3. Call service support.