Error Code Description
4069 0007 Memory tests detected fault in L3 VPD card
4069 000A Memory tests detected fault in primary I/O book
1 (slot 0)
4069 000B Memory tests detected fault in secondary I/O
book (slot 1)
4069 000C Memory tests detected fault in I/O book 3 (slot
2)
4069 000D Memory tests detected fault in I/O book 4 (slot
3)
4069 000E CUoD capacity card
4069 0010 Memory tests detected fault in Memory book
(slot 0)
4069 0011 Memory tests detected fault in Memory book
(slot 1)
4069 0012 Memory tests detected fault in Memory book
(slot 2)
4069 0013 Memory tests detected fault in Memory book
(slot 3)
4069 0014 Memory tests detected fault in Memory book
(slot 4)
4069 0015 Memory tests detected fault in Memory book
(slot 5)
4069 0016 Memory tests detected fault in Memory book
(slot 6)
4069 0017 Memory tests detected fault in Memory book
(slot 7)
4069 00B0 Memory tests detected possible problem with
bus controller or CSP code
4069 00B1 Memory tests detected possible problem with
bus controller
Action/
Possible Failing FRU
1. L3 VPD card
Location: U1.18-P1-H2.1
(Order the L3 cache module FRU to obtain
a new L3 VPD card. Return the L3 cache
module that was included in the FRU kit,
and the failing L3 VPD card as "new
defective".)
2. Primary I/O book
Location: U1.18-P1-H2
Go to "MAP 1540: Problem Isolation
Procedures" on page 253.
Go to "MAP 1540: Problem Isolation
Procedures" on page 253.
Go to "MAP 1540: Problem Isolation
Procedures" on page 253.
Go to "MAP 1540: Problem Isolation
Procedures" on page 253.
1. Replace the CUoD capacity card
Location: U1.18-P1-H2.2
2. Ask the customer to reenter the CUoD
activation keys.
Memory book (slot 0)
Location: U1.18-P1-M2
Memory book (slot 1)
Location: U1.18-P1-M3
Memory book (slot 2)
Location: U1.18-P1-M7
Memory book (slot 3)
Location: U1.18-P1-M6
Memory book (slot 4)
Location: U1.18-P1-M4
Memory book (slot 5)
Location: U1.18-P1-M8
Memory book (slot 6)
Location: U1.18-P1-M5
Memory book (slot 7)
Location: U1.18-P1-M1
1. Check for system firmware updates.
2. Primary I/O book,
Location: U1.18-P1-H2
3. Call service support.
1. Check for system firmware updates.
2. Primary I/O book,
Location: U1.18-P1-H2
3. Call service support.