Table 2. Firmware Checkpoints (continued)
Checkpoint
E84F
E850
E851
E852
E853
E854
E855
E860
E861
E870
E871
340
Eserver pSeries 670 Service Guide
Description
Initializing RTAS/operator panel interface
Initializing RTAS/cache interface
Initializing RTAS/hardware access
Initializing RTAS/PCI bus interface
Start cable ID request process
Start collecting cable IDs
Start setting RIO link speed
Initializing RTAS/power subsystem interface 1. Check for system firmware updates.
Initializing RTAS/PCI bus interface
Initializing RTAS/logs interface
Initializing RTAS/EEH handling interface
Action/
Possible Failing FRU
1. Check for system firmware updates.
2. Call service support.
1. Check for system firmware updates.
2. Call service support.
1. Check for system firmware updates.
2. Call service support.
1. Check for system firmware updates.
2. Go to "MAP 1542: I/O Problem
Isolation" on page 261.
3. Call service support.
1. Check the SPCN and RIO cabling to
the I/O subsystems
2. Disconnect then reconnect power to the
system.
3. Go to "MAP 1542: I/O Problem
Isolation" on page 261.
4. Call service support.
1. Check the SPCN and RIO cabling to
the I/O subsystems
2. Disconnect then reconnect power to the
system.
3. Go to "MAP 1542: I/O Problem
Isolation" on page 261.
4. Call service support.
1. Check the SPCN and RIO cabling to
the I/O subsystems
2. Disconnect then reconnect power to the
system.
3. Go to "MAP 1542: I/O Problem
Isolation" on page 261.
4. Call service support.
2. Call service support.
1. Check for system firmware updates.
2. Go to "MAP 1542: I/O Problem
Isolation" on page 261
3. Call service support.
1. Check for system firmware updates.
2. Call service support.
1. Check for system firmware updates.
2. Go to "MAP 1542: I/O Problem
Isolation" on page 261.
3. Call service support.