Error Code Description
101C 5Ax6 A DCA FRU whose firmware is too down-level to
function with the power subsystem has been
installed in the CEC. For the DCA to function,
the power subsystem controller must download
code to it. (The x indicates which DCA has the
down-level firmware.)
101C 6014 Overcurrent or overvoltage problem with 2.5V in
processor subsystem
101C 6114 Overcurrent or overvoltage problem with 1.8V in
processor subsystem
101C 6124 Overcurrent or overvoltage problem with 1.5V in
processor subsystem
101C 6134 Overcurrent or overvoltage problem with 1.5V in
processor subsystem
101C 6144 Overcurrent or overvoltage problem with 3.3V in
processor subsystem (oscillator)
101C 6514 Overcurrent or overvoltage problem with 5.0V in
processor subsystem (autostart, standby)
101C 6814 Overcurrent or overvoltage problem with 2.5V in
processor subsystem
101C 6914 Overcurrent or overvoltage problem with 1.8V in
processor subsystem
101C 6924 Overcurrent or overvoltage problem with 1.5V in
processor subsystem
101C 6934 Overcurrent or overvoltage problem with 1.5V in
processor subsystem
101C 6944 Overcurrent or overvoltage problem with 3.3V in
processor subsystem (oscillator)
101C 6D14 Overcurrent or overvoltage problem with 5.0V in
processor subsystem (autostart, standby)
101C 7E06 No MCMs detected OR the actual number of
MCMs does not match the expected number of
MCMs
386
Eserver pSeries 670 Service Guide
Action/
Possible Failing FRU
If the system is powered up:
1. Wait approximately 30 minutes, then press
the green start-of-service button followed by
the white end-of-service button.
2.
Look at the service action event log in
Service Focal Point. Verify that the 101C
5Ax6 error code did not reoccur; if it did not,
the update was successful. If the 101C 5Ax6
error code reoccurs, call service support.
If the system is powered down:
a. Wait approximately 30 minutes.
b. Look at the service action event log in
Service Focal Point. Verify that the 101C
5Ax6 error code did not reoccur after 30
minutes. If it did not, the update was
successful. If the 101C 5Ax6 error code
reoccurs, call service support.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
Go to "MAP 1520: Power" on page 144.
1. Verify that the processor MCMs are plugged
in a valid configuration.
2. Verify that the processor MCMs are seated
properly.
3. Verify the processor VPD cards in the
primary I/O book are of the proper number
and are positioned and seated correctly.
4. Call service support.