Error Code Description
406C 0B03 IPL detected fault in I/O book (slot 0 RIO port
3)
406C 0B10 IPL detected fault in I/O book
406C 0B11 IPL detected fault in I/O book
406C 0B12 IPL detected fault in I/O book
406C 0B13 IPL detected fault in I/O book
406C 0B14 IPL detected fault in I/O book
558
Eserver pSeries 670 Service Guide
Action/
Possible Failing FRU
1. Check for system firmware updates.
2. Check the I/O cabling between the primary
I/O book and the I/O subsystems.
3. Primary I/O book
Location: U1.18-P1-H2
4. Call service support.
1. Check for system firmware updates.
2. Check the I/O cabling between the
secondary I/O book and the I/O
subsystems.
3. Secondary I/O book
Location: U1.18-P1-H1
4. Call service support.
1. Check for system firmware updates.
2. Check the I/O cabling between the
secondary I/O book and the I/O
subsystems.
3. Secondary I/O book
Location: U1.18-P1-H1
4. Call service support.
1. Check for system firmware updates.
2. Check the I/O cabling between the
secondary I/O book and the I/O
subsystems.
3. Secondary I/O book
Location: U1.18-P1-H1
4. Call service support.
1. Check for system firmware updates.
2. Check the I/O cabling between the
secondary I/O book and the I/O
subsystems.
3. Secondary I/O book
Location: U1.18-P1-H1
4. Call service support.
1. Check for system firmware updates.
2. Check the I/O cabling between the
secondary I/O book and the I/O
subsystems.
3. Secondary I/O book
Location: U1.18-P1-H1
4. Call service support.