IBM pSeries 670 Service Manual page 742

Hide thumbs Also See for pSeries 670:
Table of Contents

Advertisement

On a partitioned system, this setting is ignored.
– Enable supplemental restart policy - The default setting is Yes. When set to Yes in a full system
partition, the service processor restarts the system when the system loses control as detected by
service processor surveillance, and either:
- The Use OS-Defined restart policy is set to No.
OR
- The Use OS-Defined restart policy is set to Yes, and the operating system has no automatic
restart policy.
If set to Yes in a partitioned system, the service processor restarts the system when the system
loses control and it is detected by service processor surveillance.
– Call-Out before restart (Enabled/Disabled) - If a restart is necessary due to a system fault, and
you are running a full system partition, you can enable the service processor to call out and report
the event. This option can be valuable if the number of these events becomes excessive, which
might signal a bigger problem.
This setting is ignored on a partitioned system.
v Power-On System
Allows immediate power-on of the system.
v Power-Off System
This option is not available on this system.
v Enable/Disable Fast System Boot
Allows the user to select the IPL type, mode, and speed of the system boot.
Attention:
Selecting the fast IPL results in several diagnostic tests being skipped and a shorter
memory test being run.