IBM pSeries 670 Service Manual page 148

Hide thumbs Also See for pSeries 670:
Table of Contents

Advertisement

Yes
Go to "Step 1321-16".
Step 1321-16
Examine the details of the ten most-recently closed service action events.
Are there any error codes or symptoms in the ten latest closed service action events that are the
same as the error code or symptom recorded in "Step 1321-1" on page 126?
No
Go to the table in "Entry MAP" on page 111.
Yes
Go to "Step 1321-17".
Step 1321-17
Examine the FRUs of the same error codes or symptoms.
Are there any FRUs in the same error codes or symptoms of the closed service action events left
to be replaced?
No
Go to the table in "Entry MAP" on page 111.
Yes
Replace the next FRU of same error codes or symptoms of the closed service action events. Go
to "MAP 0410: Repair Checkout" in RS/6000 and Eserver pSeries Diagnostic Information for
Multiple Bus Systems.
Step 1321-18
From the list of serviceable events with error code(s) of the form #xxxxxx, examine the details of each
serviceable event to display the description field of the error code(s) of the form #xxxxxx.
Step 1321-19
Double-click on the description field to view the complete text.
Step 1321-20
Perform any actions that may be listed in the descriptions of all error codes of the form #xxxxxx before
proceeding.
Step 1321-21
Did you find a problem?
No
Go to "Step 1321-7" on page 126.
Go to "MAP 0410: Repair Checkout" in RS/6000 and Eserver pSeries Diagnostic Information for
Yes
Multiple Bus Systems.
Step 1321-22
Look for and record any additional error information or software messages on the operator panel or the
console (serial TTY, Vterm, or HMC). Choose a running Linux partition (preferably the partition with the
problem).