Step 152i-20
Turn on the power.
Step 152i-21
Did the system stop with the same error code as recorded in "Step 152i-1" on page 214?
Yes
The card just reinserted is defective. Replace it. This ends the procedure.
Return the system to its original configuration.
Go to "MAP 0410: Repair Checkout" in the RS/6000 and Eserver pSeries Diagnostic Information
for Multiple Bus Systems.
No
Go to "Step 152i-22".
Step 152i-22
Have all the cards listed in "Step 152i-15" on page 215 been reinserted?
Yes
The symptom has changed. This ends the procedure.
Return the system to its original configuration.
Go to "MAP 0410: Repair Checkout" in the RS/6000 and Eserver pSeries Diagnostic Information
for Multiple Bus Systems.
No
Go to "Step 152i-19" on page 215.
Step 152i-23
Turn off the power.
Examine all the green "power good out" LEDs of both I/O subsystem DCAs.
Step 152i-24
Are all the green "power good out" LEDs of both I/O subsystem DCAs off?
Yes
Go to "Step 152i-25".
No
Call for support.
Step 152i-25
Remove the following adapter cards, if present, from the I/O subsystem. record the adapter locations:
v Adapter card at P2-I1
v Adapter card at P2-I2
v Adapter card at P2-I3
v Adapter card at P2-I4
v Adapter card at P2-I5
Step 152i-26
Turn on the power.
Step 152i-27
Did the system stop with the same error code as recorded in "Step 152i-1" on page 214?
Yes
Go to "Step 152i-33" on page 217.
No
Go to "Step 152i-28" on page 217.
216
Eserver pSeries 670 Service Guide